We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Agriculture/Analysis of Air Temperature and Humidity Distributions and Energy Consumptions according to Use of Air Circulation Fans in a Single-span Greenhouse
PeriodicalsAgriculture

Analysis of Air Temperature and Humidity Distributions and Energy Consumptions according to Use of Air Circulation Fans in a Single-span Greenhouse

Checking your access to this record.

Abstract & Overview

The aim of this study was to compare and analyze air temperature and humidity distribution and energy consumptions according to using air circulation fans in single-span greenhouses.The greenhouses located in Cheongnam-myeon, Cheongyang-gun, Chungcheongnam-do, Korea.There were cherry tomatoes in the greenhouses and the size of greenhouses was as follows;ridge height : 3.2 m, wide : 6 m, length : 95 m.The heating system was composed of a hot-water boiler and 6 FCUs(Fan Coil Unit)-4 FCUs were on bottom with duct and 2 FCUs were installed at 2.0 m.A total of 18 air circulation fans(impeller's diameter : 230 mm) were bilaterally arranged in 2 rows in the experimental greenhouse.The sensors for measuring air temperature and humidity were located at a quarter and three quarters of a length.The height of sensors were 0.8 m, 1.8 m.To calculate energy consumption in greenhouses, water temperature at inlet and outlet in a water pump, volume of water were measured.Form February 3rd to March 23th, temperature, humidity and energy consumptions were measured during heating time(6pm~7am).In a greenhouse without fans, the average differences of temperature and humidity were 0.75 o C, 2.31%, respectively.The operation of fans showed their differences to 0.42 o C, 1.8%.The standard deviation of temperature and humidity between measuring points in the greenhouse with fans was lower than the greenhouse without fans.Total energy consumptions in a greenhouse without fans were 4,673 kWh.In the greenhouse with fans, the total energy consumptions were 4,009 kWh.The energy consumptions in a greenhouse with fans 14.2% were less than the greenhouse without fans.Therefore, air circulation makes temperature and humidity uniform and saves energy consumptions for heating.

Cite this record

Tae Seok Lee, Geum Choon Kang, Hyung-Kweon Kim, Jong Pil Moon, Sung Sik Oh, Jin Kyung Kwon (2017). Analysis of Air Temperature and Humidity Distributions and Energy Consumptions according to Use of Air Circulation Fans in a Single-span Greenhouse. Protected horticulture and Plant Factory, 26(4), 276–282. https://doi.org/10.12791/ksbec.2017.26.4.276

Copy in another style

Lee, T. S., Kang, G. C., Kim, H., Moon, J. P., Oh, S. S., & Kwon, J. K. (2017). Analysis of Air Temperature and Humidity Distributions and Energy Consumptions according to Use of Air Circulation Fans in a Single-span Greenhouse. Protected horticulture and Plant Factory, 26(4), 276–282. https://doi.org/10.12791/ksbec.2017.26.4.276
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.