Abstract & Overview
Objective To establish a quantitative method for the determination of narcissoside in Opuntia stricta (Haw.) Haw. var. dillenii (Ker Gawl.) Benson and to improve its quality control standard. Methods High-performance liquid chromatography (HPLC) was used to determine the content of narcissoside. The chromatographic conditions were as follows: a C18 column was employed with acetonitrile-0.1% formic acid aqueous solution (18:82, v/v) as the mobile phase at a fl ow rate of 1.0 mL/min. The detection wavelength was 254 nm, the column temperature was maintained at 30 °C, and the injection volume was 10 μL. Results Good linearity was observed over the range of 3.54–56.64 μg (R² = 0.9997). The relative standard deviations (RSDs) of precision, stability, and repeatability were all less than 2.0%. The average recovery was 98.79% with an RSD of 1.15% (n = 6). Based on the determination of three batches of samples, the content of narcissoside was preliminarily specifi ed as not less than 0.0105% in Opuntia stricta (Haw.) Haw. var. dillenii (Ker Gawl.) Benson. Conclusion The established HPLC method is simple, stable, and accurate, providing a reliable reference for the quality evaluation and quality control of Opuntia stricta var. dillenii.