We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Civil & Construction Engineering/Influence of rebar tying wire gauge and knot spacing on the positional stability of beam reinforcement cages during concrete pouring vibration
PeriodicalsCivil & Construction Engineering

Influence of rebar tying wire gauge and knot spacing on the positional stability of beam reinforcement cages during concrete pouring vibration

Checking your access to this record.

Abstract & Overview

Positional stability of a reinforcement cage is defined as the ability of the assembled bar arrangement to maintain its designed geometry cover, bar spacing and straightness during the dynamic disturbance of concrete placement and internal vibration. This research investigated how two controllable site variables, the gauge (diameter) of the galvanised tying wire and the longitudinal spacing of the wire knots, affect the maximum lateral displacement of a beam reinforcement cage subjected to simulated pouring vibration. Forty-five beam cages (300 mm × 500 mm cross-section, 2 000 mm length, four 16 mm longitudinal bars, 8 mm stirrups at 200 mm centres) were assembled by an experienced steel fixer using four wire gauges (0.8, 1.0, 1.2 and 1.6 mm diameter) at three knot spacings (150, 200 and 300 mm centres), plus a control with no tying wire (bars held by friction and gravity alone). Each of the 12 gauge-spacing combinations was tested in triplicate. The cages were placed in timber formwork, fitted with four LVDT displacement sensors at mid-span, and subjected to three 20-second passes of a 40 mm internal poker vibrator operating at 12 000 rpm, replicating the vibration energy of a typical site pour. The control cages displaced an average of 14.2 mm far beyond the 5 mm tolerance recommended by EN 13670 confirming that tying wire is not cosmetic but structurally necessary. Among the wired cages, the 0.8 mm wire at 300 mm spacing produced the worst result (8.4 mm), while the 1.6 mm wire at 150 mm spacing produced the best (1.2 mm). A two-way ANOVA showed that wire gauge explained 62 % of the variance in displacement (F = 89.4, p < 0.001) and knot spacing explained 28 % (F = 40.1, p < 0.001); their interaction was modest (4 %, p = 0.03). Every combination using 1.2 mm wire stayed below the 5 mm limit regardless of spacing, whereas the 0.8 mm wire exceeded the limit at spacings wider than 150 mm. These results provide quantified guidance for site supervisors: specifying a minimum wire gauge of 1.0 mm at 200 mm maximum knot spacing, or 1.2 mm at any spacing up to 300 mm, keeps beam cages within the cover tolerance during vibration. The findings apply to simply supported beams with four-bar cages and moderate vibration energy; deeper beams, heavier cages and high-frequency vibrators may require tighter specifications.

Cite this record

Radek Vlček (2026). Influence of rebar tying wire gauge and knot spacing on the positional stability of beam reinforcement cages during concrete pouring vibration. International Journal of Civil Engineering and Construction, 5(2), 54–58. https://doi.org/10.22271/27078329.2026.v5.i2a.85

Copy in another style

Vlček, R. (2026). Influence of rebar tying wire gauge and knot spacing on the positional stability of beam reinforcement cages during concrete pouring vibration. International Journal of Civil Engineering and Construction, 5(2), 54–58. https://doi.org/10.22271/27078329.2026.v5.i2a.85
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.