We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Medical Sciences/Optimization of electrode position and electric pulse amplitude in electrochemotherapy
PeriodicalsMedical Sciences

Optimization of electrode position and electric pulse amplitude in electrochemotherapy

Checking your access to this record.

Abstract & Overview

Background.In addition to the chemotherapeutic drug being present within the tumor during electric pulse delivery, successful electrochemotherapy requires the entire tumor volume to be subjected to a sufficiently high electric field, while the electric field in the surrounding healthy tissue is as low as possible to prevent damage.Both can be achieved with appropriate positioning of the electrodes and appropriate amplitude of electric pulses.Methods.We used 3D finite element numerical models and a genetic optimization algorithm to determine the optimum electrode configuration and optimum amplitude of electric pulses for treatment of three subcutaneous tumor models of different shapes and sizes and a realistic brain tumor model acquired from medical images.Results.In all four tumor cases, parallel needle electrode arrays were a better choice than hexagonal needle electrode arrays, since their utilization required less electric current and caused less healthy tissue damage.In addition, regardless of tumor geometry or needle electrode configuration, the optimum depth of electrode insertion was in all cases deeper than the deepest part of the tumor.Conclusions.Our optimization algorithm was able to determine the best electrode configuration in all four presented models and with further improvement it could be a useful tool in clinical electrochemotherapy treatment planning.

Cite this record

Anže Županič, Selma Čorović, Damijan Miklavčič (2008). Optimization of electrode position and electric pulse amplitude in electrochemotherapy. Radiology and Oncology, 42(2), 93–101. https://doi.org/10.2478/v10019-008-0005-5

Copy in another style

Županič, A., Čorović, S., & Miklavčič, D. (2008). Optimization of electrode position and electric pulse amplitude in electrochemotherapy. Radiology and Oncology, 42(2), 93–101. https://doi.org/10.2478/v10019-008-0005-5
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.