Abstract & Overview
The radiolytic products of TBP extraction system have been analysed qualitatively and quantitatively with infrared spectrophotometer,gas chromatography-mass spectrometry and liquid chromatography-mass spectrometry.The possible molecular formulas of the radiolytic products were concluded.The concentrations of carbonyl compounds,hydroxamic acids,dibutyl phosphate and monobutyl phosphate were measured in the extraction system after radiolyzed.