We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Medical Sciences/Evaluation of an automated knowledge based treatment planning system for head and neck
PeriodicalsMedical Sciences

Evaluation of an automated knowledge based treatment planning system for head and neck

Checking your access to this record.

Abstract & Overview

BACKGROUND: This study evaluated an automated inverse treatment planning algorithm, Pinnacle Auto-Planning (AP), and compared automatically generated plans with historical plans in a large cohort of head and neck cancer patients. METHODS: Fifty consecutive patients treated with volumetric modulated arc therapy (Eclipse, Varian Medical System, Palo Alto, CA) for head and neck were re-planned with AP version 9.10. Only one single cycle of plan optimization using one single template was allowed for AP. The dose to the planning target volumes (PTV's; 3-4 dose levels), the organs at risk (OAR's) and the effective working time for planning was evaluated. Additionally, two experienced radiation oncologists blind-reviewed and ranked 10 plans. RESULTS: Dose coverage and dose homogeneity of the PTV were significantly improved with AP, however manually optimized plans showed significantly improved dose conformity. The mean dose to the parotid glands, oral mucosa, swallowing muscles, dorsal neck tissue and maximal dose to the spinal cord were significantly reduced with AP. In 64 % of the plans, the mean dose to any OAR (spinal cord excluded) was reduced by >20 % with AP in comparison to the manually optimized plans. In 12 % of the plans, the manually optimized plans showed reduced doses by >20 % in at least one OAR. The experienced radiation oncologists preferred the AP plan and the clinical plan in 80 and 20 % of the cases, respectively. The average effective working time was 3.8 min ± 1.1 min in comparison to 48.5 min ± 6.0 min using AP compared to the manually optimized plans, respectively. CONCLUSION: The evaluated automated planning algorithm achieved highly consistent and significantly improved treatment plans with potentially clinically relevant OAR sparing by >20 % in 64 % of the cases. The effective working time was substantially reduced with Auto-Planning.

Cite this record

Jerome Krayenbuehl, Ian Norton, Gabriela Studer, Matthias Gückenberger (2015). Evaluation of an automated knowledge based treatment planning system for head and neck. Radiation Oncology, 10(1), 226–226. https://doi.org/10.1186/s13014-015-0533-2

Copy in another style

Krayenbuehl, J., Norton, I., Studer, G., & Gückenberger, M. (2015). Evaluation of an automated knowledge based treatment planning system for head and neck. Radiation Oncology, 10(1), 226–226. https://doi.org/10.1186/s13014-015-0533-2
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.