We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Civil & Construction Engineering/Case study of load-bearing precast wall system subject to low seismic intensity by linear and nonlinear analyses
PeriodicalsCivil & Construction Engineering

Case study of load-bearing precast wall system subject to low seismic intensity by linear and nonlinear analyses

Checking your access to this record.

Abstract & Overview

This paper investigates the behaviour of load-bearing precast wall system (namely the HC Precast System − HCPS) subject to seismicity in Malaysia. Recent tremors felt across the country heeded the call for the need of seismic design guidelines to be implemented. For this study, the design ground acceleration for Malaysia has not been finalized. Throughout the years, several schools of thought that occurred among different researchers pertaining to the value of design ground acceleration, ranging from 0.05 g to 0.1 g. The implications of the selected values can be great especially in designing new buildings or retrofitting existing ones. Thus, linear analysis using Modal Response Spectrum Analysis (MRSA) and nonlinear pushover analysis of representative HCPS were performed for this study. The finite element (FE) model focused particularly on the nonlinear behaviour of the interface between a precast wall and cast in-situ column. Prior to the modal and pushover analyses, the FE model was validated against quasi-static cyclic test results of identical precast system obtained from literature. Differences between the MRSA and pushover approaches are presented and discussed. Performance levels of the structural system were subjected to three levels of design ground acceleration (0.05, 0.075 and 0.1 g) have been included.

Cite this record

Patrick Liq Yee Tiong, S.P. Chiew, Beng Hur Teow (2016). Case study of load-bearing precast wall system subject to low seismic intensity by linear and nonlinear analyses. Case Studies in Structural Engineering, 6, 11–21. https://doi.org/10.1016/j.csse.2016.05.001

Copy in another style

Tiong, P. L. Y., Chiew, S., & Teow, B. H. (2016). Case study of load-bearing precast wall system subject to low seismic intensity by linear and nonlinear analyses. Case Studies in Structural Engineering, 6, 11–21. https://doi.org/10.1016/j.csse.2016.05.001
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.