We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Mathematics/Optimizing the Performance of AI Model for Non-Invasive Continuous Glucose Monitoring: Hyperparameter Tuning and Random Oversampling Approach
PeriodicalsMathematics

Optimizing the Performance of AI Model for Non-Invasive Continuous Glucose Monitoring: Hyperparameter Tuning and Random Oversampling Approach

Checking your access to this record.

Abstract & Overview

Diabetes Mellitus (DM) as a non-communicable disease (NCD) continues to increase every year. Continuous glucose monitoring (CGM) is essential for effective DM management. However, existing disposable glucose monitoring methods still rely on invasive techniques, cause pain, and lack continuous monitoring capabilities. On the other hand, non-invasive techniques are not feasible for CGM due to the biometric data's complexity and the classification system's inadequate performance. This study aims to develop a non-invasive technology to improve the performance of a non-invasive blood glucose classification system using Artificial Intelligence (AI), specifically Convolutional Neural Network (CNN) and an oversampling technique. The oversampling technique could improve data quantity by balancing the amount of data for each class. This study recruited twenty-three participants in the age range of 20 to 22 years comprising seven females and fifteen males. During data recording sessions, blood glucose levels were simultaneously assessed using a gold-standard glucometer and a non-invasive CGM prototype. The proposed CNN model successfully improved the classification accuracy of non-invasive blood glucose monitoring significantly. With the implementation of oversampling for augmenting the data, the accuracy of the proposed model increased to more than 88%. This study concludes that non-invasive approaches combined with AI technology have the potential to provide a convenient and pain-free alternative to traditional monitoring methods, significantly improving diabetes management and enhancing the overall quality of life for those affected by this condition. These findings could revolutionize the field of diabetes management, offering a more comfortable and accurate monitoring solution that could potentially transform the lives of millions of diabetes patients.

Cite this record

Karisma Trinanda Putra, Mahendro Prasetyo Kusumo, Prayitno Prayitno, Darma Wicaksana, Ahmad Zaki Arrayyan, Sakca Garda Pratama, et al. (2024). Optimizing the Performance of AI Model for Non-Invasive Continuous Glucose Monitoring: Hyperparameter Tuning and Random Oversampling Approach. JOIV International Journal on Informatics Visualization, 8(2), 991–991. https://doi.org/10.62527/joiv.8.2.2047

Copy in another style

Putra, K. T., Kusumo, M. P., Prayitno, P., Wicaksana, D., Arrayyan, A. Z., Pratama, S. G., Al-Kamel, M. A., & Chen, H. (2024). Optimizing the Performance of AI Model for Non-Invasive Continuous Glucose Monitoring: Hyperparameter Tuning and Random Oversampling Approach. JOIV International Journal on Informatics Visualization, 8(2), 991–991. https://doi.org/10.62527/joiv.8.2.2047
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.