We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Electrical Engineering/Cantilever beam temperature sensors for biological applications
PeriodicalsElectrical Engineering

Cantilever beam temperature sensors for biological applications

Checking your access to this record.

Abstract & Overview

This review presents two types of cantilever beams employed as highly sensitive temperature sensors. One type is fabricated from composite materials and is operated in the deflection mode. The second type, used as a temperature sensor and presented in this review, is a resonant cantilever beam. The materials used for the fabrication of the bimaterial cantilever beam are silicon or silicon nitride and thin metallic films such as gold or aluminum. When the temperature changes, the different coefficients of thermal expansion of the metal and silicon cause the sensor to deflect. Considering the models of temperature measurement for biological cells, the heat should be applied locally at the tip of the cantilever beam. Formulas for the calculation of the deflection as a function of incident power applied at the free end of the cantilever beam operated in a liquid are presented in this review. The natural convective heat transfer coefficient was estimated by using the mathematical model and experimental values. For biological applications, the cantilever beam temperature sensor was operated in a liquid, and the heat transfer coefficients were between 381 and 642 W/m2K when the temperature applied to the cantilever's free end varied from 28 to 71.8 °C. The resonant cantilever beam was also demonstrated as a sensitive temperature sensor for biological applications. As a thermogenic sample, brown fat cells (BFCs), which are related to metabolic heat production, are employed. The working principle of the resonator cantilever beam temperature sensor is based on the shift in resonant frequency in response to temperature changes. The resonant frequency and the temperature coefficient were 960 kHz and 22.0 ppm/K, respectively. The measurements were performed by stimulating the activity of BFCs by flowing a norepinephrine (NE) solution (1 µM).

Cite this record

Masaya Toda, Naoki Inomata, Takahito Ono, Ioana Voiculescu (2017). Cantilever beam temperature sensors for biological applications. IEEJ Transactions on Electrical and Electronic Engineering, 12(2), 153–160. https://doi.org/10.1002/tee.22360

Copy in another style

Toda, M., Inomata, N., Ono, T., & Voiculescu, I. (2017). Cantilever beam temperature sensors for biological applications. IEEJ Transactions on Electrical and Electronic Engineering, 12(2), 153–160. https://doi.org/10.1002/tee.22360
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.