Home/e-Resources/Biotechnology/Oriented suspension mechanics with applications to flow linear dichrosim spectroscopy and pathogen detection
PeriodicalsBiotechnology

Oriented suspension mechanics with applications to flow linear dichrosim spectroscopy and pathogen detection

arXiv2019

Checking your access to this record.

Abstract & Overview

Flow linear dichroism is a biophysical spectroscopic technique that exploits the shear-induced alignment of elongated particles in suspension. Motivated by the broad aim of optimising the sensitivity of this technique, and more specifically by a handheld synthetic biotechnology prototype for waterborne-pathogen detection, a model of steady and oscillating pressure-driven channel flow and orientation dynamics of a suspension of slender microscopic fibres is developed. The model couples the Fokker-Planck equation for Brownian suspensions with the narrow channel flow equations, the latter modified to incorporate mechanical anisotropy induced by the particles. The linear dichroism signal is estimated through integrating the perpendicular components of the distribution function via an appropriate formula which takes the bi-axial nature of the orientation into account. For the specific application of pathogen detection via binding of M13 bacteriophage, it is found that increases in the channel depth are more significant in improving the linear dichroism signal than increases in the channel width. Increasing channel depth to $2~$mm and pressure gradient to $5 \times 10^4~$Pa/m essentially maximises the alignment. Oscillating flow can produce nearly equal alignment to steady flow at appropriate frequencies, which has significant potential practical value in the analysis of small sample volumes.

Cite this record

G. Cupples, D. J. Smith, M. R. Hicks, R. J. Dyson (2019). Oriented suspension mechanics with applications to flow linear dichrosim spectroscopy and pathogen detection. arXiv. https://library.shubhaarti.com/content/edee23a0-37a0-4d2b-845d-873a298115a0

Copy in another style

Cupples, G., Smith, D. J., Hicks, M. R., & Dyson, R. J. (2019). Oriented suspension mechanics with applications to flow linear dichrosim spectroscopy and pathogen detection. arXiv. https://library.shubhaarti.com/content/edee23a0-37a0-4d2b-845d-873a298115a0