We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Biomedical Engineering/Cutting a mediolateral episiotomy at the correct angle: evaluation of a new device, the Episcissors-60
PeriodicalsBiomedical Engineering

Cutting a mediolateral episiotomy at the correct angle: evaluation of a new device, the Episcissors-60

Checking your access to this record.

Abstract & Overview

BACKGROUND: Anal incontinence is nine times more prevalent in women than in men due to obstetric anal sphincter injury (OASI). OASI is linked to midline episiotomies and mediolateral episiotomies with post-delivery angles of <30 and >60 degrees. Studies show that doctors and midwives are unable to correctly "eyeball" the safe angle required due to perineal stretching by the fetal head at crowning. A new scissor instrument (Episcissors-60) was devised to allow cutting a mediolateral episiotomy at a fixed angle of 60 degrees from the perineal midline. METHODS: Scissors with a marker guide limb pointing towards the anus were devised, ensuring an angle of 60 degrees between the scissor blades and the guide limb. This device was initially tested in models. Post-delivery angles were recorded on transparencies and analyzed by an author blinded to clinical details. Accoucheurs were asked to rate the ease of use on a 5-point scale. RESULTS: Of the 17 women, 14 delivered with ventouse, two with forceps, and one with sequential ventouse-forceps. Indications for instrumental delivery were suboptimal cardiotocogram and/or prolonged second stage of labor. Mean birth weight was 3.41 (2.92-4.12) kg. A mean post-delivery angle of 42.4±7 (range 30-60, median 43) degrees (95% confidence interval 38.8-46) was achieved with the Episcissors-60 instrument. Eighty-eight percent of clinicians agreed or strongly agreed that the scissors were easy to use. CONCLUSION: The Episcissors-60 delivered a consistent post-delivery angle of 43 degrees. They could replace "eyeballing" when performing mediolateral episiotomies and form part of a preventative strategy to reduce OASI.

Cite this record

Kapoor, Heidi J. Hollands, Laurie Barron, Robert M. Freeman (2014). Cutting a mediolateral episiotomy at the correct angle: evaluation of a new device, the Episcissors-60. Medical Devices Evidence and Research, 7, 23–23. https://doi.org/10.2147/mder.s60056

Copy in another style

Kapoor, Hollands, H. J., Barron, L., & Freeman, R. M. (2014). Cutting a mediolateral episiotomy at the correct angle: evaluation of a new device, the Episcissors-60. Medical Devices Evidence and Research, 7, 23–23. https://doi.org/10.2147/mder.s60056
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.