We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Chemistry/OXYGEN SENSOR CALIBRATION FOR LBE COOLANT CHEMISTRY CONTROL
Conference ProceedingsChemistry

OXYGEN SENSOR CALIBRATION FOR LBE COOLANT CHEMISTRY CONTROL

Checking your access to this record.

Abstract & Overview

The results from a series of oxygen sensor calibrations in a lead-bismuth eutectic (LBE) system are presented. The yttria-stabilized zirconia (YSZ) | Bi/Bi_2O_3 sensors developed at LANL (LA-OS) are shown to behave quite uniformly according to the Nernst law. The sensors are being calibrated in a small stainless steel (316L) LBE container with controlled gas injection (helium or its mixture with oxygen or hydrogen). The apparatus is placed on a rocker to stir LBE. To study the dynamic range and responses, some sensors have been subject to swings between oxygen saturation and depletion limited by magnetite dissociation, and thermal cycling. The measured emf agrees with the theoretically predicted limits very well. For sensor calibrations the oxygen in LBE is first adjusted to a desired level estimated from the Nernst law at the highest calibration temperature. The apparatus is then closed. After certain waiting time, the LBE temperature is gradually reduced in controlled ramps, and the OS output is recorded. It is found that the V-T curves first follow the constant oxygen concentration lines according to the Nernst law, then turn to the oxygen saturation line. The uncertainty of the sensor output is preliminarily estimated to be within 20% of the theoretical value.

Cite this record

Ning Li, Wei Hang, Timothy W. Darling (2003). OXYGEN SENSOR CALIBRATION FOR LBE COOLANT CHEMISTRY CONTROL. The Proceedings of the International Conference on Nuclear Engineering (ICONE). https://doi.org/10.1299/jsmeicone.2003.196

Copy in another style

Li, N., Hang, W., & Darling, T. W. (2003). OXYGEN SENSOR CALIBRATION FOR LBE COOLANT CHEMISTRY CONTROL. The Proceedings of the International Conference on Nuclear Engineering (ICONE). https://doi.org/10.1299/jsmeicone.2003.196
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.