We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Artificial Intelligence & Machine Learning/Digital Impedance Bridge for Four-Terminal-Pair AC Resistor Calibration up to 20 kHz
PeriodicalsArtificial Intelligence & Machine Learning

Digital Impedance Bridge for Four-Terminal-Pair AC Resistor Calibration up to 20 kHz

Checking your access to this record.

Abstract & Overview

For this study, a substitution principle-based impedance bridge has been developed to calibrate AC resistors in a four-terminal-pair (4TP) configuration. The calibration is performed in the full complex plane for resistances ranging from 100 mΩ to 400 Ω and frequencies of between 50 Hz and 20 kHz. The automated bridge is based on four resistors associated with two high-impedance stages. The balancing of the bridge is achieved by means of PXI modules. The bridge is automatically balanced via a simplex top-down algorithm. The new bridge is primarily used for the measurement chain of AC standard resistors defined in a 4TP configuration at LNE, which are used for routine customer calibrations. The traceability of LNE’s standard resistors when defined in a 4TP configuration is ensured by a measurement chain from a 1 kΩ reference resistor using the new bridge. The reference resistor was calibrated previously via comparison with a calculable resistor up to 20 kHz. The bridge was validated via comparison with calibration results obtained in 1983 and 2009. For a resistor of 1 Ω at 1 kHz, the uncertainty of the series resistance variation and the phase shift are less than 6 µΩ/Ω (k = 1) and 6 µrad (k = 1), respectively.

Cite this record

Mohamed Ouameur, Renata T. de Barros e Vasconcellos, Mohamed Agazar (2024). Digital Impedance Bridge for Four-Terminal-Pair AC Resistor Calibration up to 20 kHz. Metrology, 4(1), 1–14. https://doi.org/10.3390/metrology4010001

Copy in another style

Ouameur, M., Vasconcellos, R. T. D. B. E., & Agazar, M. (2024). Digital Impedance Bridge for Four-Terminal-Pair AC Resistor Calibration up to 20 kHz. Metrology, 4(1), 1–14. https://doi.org/10.3390/metrology4010001
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.