Abstract & Overview

A comprehensive R&D has been conducted on multianode photomultipliers, leading to the diagnosis of non-trivial problems in the design of the detector Read-out. A major ageing problem has been identified, requiring to define an adequate operation point of the PMT, yielding constraints to the design of the VFE board. The prototype Read-Out electronics, which required a new iteration regarding as the ageing of the phototubes, has been succesfully designed, realized and tested. Photomultipliers and electronics Read-Out are about to be produced.

Cite this record

S. Monteil (2005). LHCB PRESHOWER PHOTODETECTOR AND ELECTRONICS. International Conference on Calorimetry in Particle Physics (CALOR). https://doi.org/10.1142/9789812701978_0020

Copy in another style

Monteil, S. (2005). LHCB PRESHOWER PHOTODETECTOR AND ELECTRONICS. International Conference on Calorimetry in Particle Physics (CALOR). https://doi.org/10.1142/9789812701978_0020