Abstract & Overview
This scientific paper provides review of the methods used for the analysis of the thermal state of the turbogenerator including its advantages and drawbacks. The need for the analysis of the temperature field of the turbo-generator rotor with intermediate hydrogen cooling has been substantiated. The method of equivalent circuits has widely been used until recently. However, it allows just for the determination of the average elevation of the temperature of rotor units and it fails to take into consideration the complicated geometry of turbo-generator elements. This method was realized in the computer Solid Works environment. Consideration was given to heat-transfer models (boundary conditions of the third kind) intended for the closure of the mathematical model for the thermal state of the turbo-generator rotor. The formulas used for the determination of heat emission coefficients that describe the heat transfer conditions at the boundaries of the system with cooling medium should be modified and substantiated.