We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Mechanical Engineering/Assessment of Backscattered Radiation Dose at Exposed Object’s Level during X-Ray Examinations
PeriodicalsMechanical Engineering

Assessment of Backscattered Radiation Dose at Exposed Object’s Level during X-Ray Examinations

Checking your access to this record.

Abstract & Overview

This paper estimates backscattered radiation doses at patient’s positioning level (exposed object) using different X-ray tubes. The effects of different exposure sittings (X-ray tube voltage, exposure intensity, exposed area, dosimeter position, and distance between X-ray tube and imaged object surface) on backscattered radiation doses are estimated using different dosimeters and x-ray units. The quantity of recorded backscattered radiation dose -which reflects from patient’s table or bucky to image receptor and exposed patient - is determined by the position of dosimeter between exposed object’s table or bucky and X-ray tube according to backscatter angle, at higher backscattered angle, the dosimeter records more backscattered dose. The results showed that, increase in kVp, exposure intensity, and exposed area led to a concomitant increase in the quantity of backscattered radiation, whereas the Increase in distanc e between X-ray tube (source) and imaged object surface reduces the amount of backscattered radiation dose. As well as, there is no remarkable difference in recorded backscattered dose due to the position of X-ray tube or the direction of incident X-ray photons.

Cite this record

Abdullah Taher Naji, Gobran N. Ali (2020). Assessment of Backscattered Radiation Dose at Exposed Object’s Level during X-Ray Examinations. Journal of Modern Mechanical Engineering and Technology, 7, 74–81. https://doi.org/10.31875/2409-9848.2020.07.10

Copy in another style

Naji, A. T., & Ali, G. N. (2020). Assessment of Backscattered Radiation Dose at Exposed Object’s Level during X-Ray Examinations. Journal of Modern Mechanical Engineering and Technology, 7, 74–81. https://doi.org/10.31875/2409-9848.2020.07.10
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.