We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Dentistry/Magnitude of beam-hardening artifacts produced by gutta-percha and metal posts on cone-beam computed tomography with varying tube current
PeriodicalsDentistry

Magnitude of beam-hardening artifacts produced by gutta-percha and metal posts on cone-beam computed tomography with varying tube current

Checking your access to this record.

Abstract & Overview

PURPOSE: This study was performed to evaluate the magnitude of artifacts produced by gutta-percha and metal posts on cone-beam computed tomography (CBCT) scans obtained with different tube currents and with or without metal artifact reduction (MAR). MATERIALS AND METHODS: A tooth was inserted in a dry human mandible socket, and CBCT scans were acquired after root canal instrumentation, root canal filling, and metal post placement with various tube currents with and without MAR activation. The artifact magnitude was assessed by the standard deviation (SD) of gray values and the contrast-to-noise ratio (CNR) at the various distances from the tooth. Data were compared using multi-way analysis of variance. RESULTS: >0.05). CONCLUSION: Increasing the tube current from 4 mA to 8 mA may reduce the magnitude of artifacts from metal posts. The magnitude of artifacts arising from metal posts was significantly higher at distances of 1.5 cm or less than at greater distances. MAR usage improved image quality near the metal post, but had no significant influence farther than 1.5 cm from the tooth.

Cite this record

Hugo Gaêta‐Araujo, Eduarda Helena Leandro Nascimento, Rocharles Cavalcante Fontenele, Arthur Xavier Maseti Mancini, Deborah Queiroz Freitas, Christiano Oliveira‐Santos (2020). Magnitude of beam-hardening artifacts produced by gutta-percha and metal posts on cone-beam computed tomography with varying tube current. Imaging Science in Dentistry, 50(1), 1–1. https://doi.org/10.5624/isd.2020.50.1.1

Copy in another style

Gaêta‐Araujo, H., Nascimento, E. H. L., Fontenele, R. C., Mancini, A. X. M., Freitas, D. Q., & Oliveira‐Santos, C. (2020). Magnitude of beam-hardening artifacts produced by gutta-percha and metal posts on cone-beam computed tomography with varying tube current. Imaging Science in Dentistry, 50(1), 1–1. https://doi.org/10.5624/isd.2020.50.1.1
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.