We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Physics/Can medical learners achieve point-of-care ultrasound competency using a high-fidelity ultrasound simulator?: a pilot study
PeriodicalsPhysics

Can medical learners achieve point-of-care ultrasound competency using a high-fidelity ultrasound simulator?: a pilot study

Checking your access to this record.

Abstract & Overview

BACKGROUND: Point-of-care ultrasound (PoCUS) is currently not a universal component of curricula for medical undergraduate and postgraduate training. We designed and assessed a simulation-based PoCUS training program for medical learners, incorporating image acquisition and image interpretation for simulated emergency medical pathologies. We wished to see if learners could achieve competency in simulated ultrasound following focused training in a PoCUS protocol. METHODS: Twelve learners (clerks and residents) received standardized training consisting of online preparation materials, didactic teaching, and an interactive hands-on workshop using a high-fidelity ultrasound simulator (CAE Vimedix). We used the Abdominal and Cardiothoracic Evaluation by Sonography (ACES) protocol as the curriculum for PoCUS training. Participants were assessed during 72 simulated emergency cardiorespiratory scenarios. Their ability to complete an ACES scan independently was assessed. Data was analyzed using R software. RESULTS: Participants independently generated 574 (99.7%) of the 576 expected ultrasound windows during the 72 simulated scenarios and correctly interpreted 67 (93%) of the 72 goal-directed PoCUS scans. CONCLUSIONS: Following a focused training process using medical simulation, medical learners demonstrated an ability to achieve a degree of competency to both acquire and correctly interpret cardiorespiratory PoCUS findings using a high-fidelity ultrasound simulator.

Cite this record

Adam R Parks, Paul Atkinson, Glenn Verheul, Denise LeBlanc-Duchin (2013). Can medical learners achieve point-of-care ultrasound competency using a high-fidelity ultrasound simulator?: a pilot study. The Ultrasound Journal, 5(1), 9–9. https://doi.org/10.1186/2036-7902-5-9

Copy in another style

Parks, A. R., Atkinson, P., Verheul, G., & LeBlanc-Duchin, D. (2013). Can medical learners achieve point-of-care ultrasound competency using a high-fidelity ultrasound simulator?: a pilot study. The Ultrasound Journal, 5(1), 9–9. https://doi.org/10.1186/2036-7902-5-9
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.