We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Electrical Engineering/A non-invasive method of glucose monitoring using FR4 material based microwave antenna sensor
PeriodicalsElectrical Engineering

A non-invasive method of glucose monitoring using FR4 material based microwave antenna sensor

Checking your access to this record.

Abstract & Overview

This work presents a unique non-invasive method for monitoring glucose levels in blood using a planar Yagi–Uda antenna as a microwave sensor. The proposed antenna, operating at 5.5 GHz, exhibits a directional radiation pattern with a peak gain of 6.74 dBi. A low-cost FR4 material of size 30 mm × 40 mm × 1.6 mm is used as a dielectric substrate. A human finger phantom, comprising layers of skin, fat, blood, and bone, is created at 5.5 GHz in EM simulation tool for mimicking a real human finger. The finger phantom is positioned at different locations around the antenna and corresponding frequency shifts are remarked to a variation in glucose concentration from 0–500 mg/dL. An exemplary frequency shift of maximum 26 MHz is recorded when the phantom is placed at the bottom of the antenna. Time domain analysis is also carried out to understand the effect of glucose concentration variation on the output signal amplitude and delay. Simulated antenna results are found to be in stupendous agreement with the measured results. An experiment of placing a real human finger around the fabricated antenna also presents a splendid correspondence with the simulated results. Hence, this mechanism can be expedient for monitoring glucose levels in blood.

Cite this record

Anveshkumar Nella, Rabah W. Aldhaheri, Jagadeesh Babu Kamili, Nebras Mohammed Kamal A. Sobahi (2023). A non-invasive method of glucose monitoring using FR4 material based microwave antenna sensor. Science and Engineering of Composite Materials, 30(1), 20220187. https://doi.org/10.1515/secm-2022-0187

Copy in another style

Nella, A., Aldhaheri, R. W., Kamili, J. B., & Sobahi, N. M. K. A. (2023). A non-invasive method of glucose monitoring using FR4 material based microwave antenna sensor. Science and Engineering of Composite Materials, 30(1), 20220187. https://doi.org/10.1515/secm-2022-0187
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.