We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Computer Science & Information Technology/Dye‐based recombinase‐aided amplification assay with enhanced sensitivity and specificity
PeriodicalsComputer Science & Information Technology

Dye‐based recombinase‐aided amplification assay with enhanced sensitivity and specificity

Checking your access to this record.

Abstract & Overview

Background Fluorescent recombinase‐aided amplification (RAA) assays are increasingly being used in the detection of a variety of pathogens and have the advantages of rapidity and simplicity and similar sensitivity and specificity, compared with real‐time PCR (qPCR) assays, but they require a complex probe design. To eliminate the addition of fluorescent probes for RAA, an EvaGreen dye‐based recombinase‐aided amplification (EvaGreen‐RAA) assay using self‐avoiding molecular recognition system (SAMRS) primers was developed. Methods The SAMRS primers effectively avoided the production of primer dimers, thus improving the detection sensitivity, while EvaGreen dye was used to quantitatively measure the amplified products in real time. Using Staphylococcus aureus (SA) and Listeria monocytogenes (LM) as examples, EvaGreen‐RAA with SAMRS primers was developed. As a reference and comparison, a traditional fluorescence probe RAA method and a RAA with SAMRS primers (SAMRS‐RAA) for detecting SA and LM were also investigated. Serial dilutions of recombinant plasmids were used to evaluate the sensitivity of the assays. Unenriched and enriched simulated milk samples were used to evaluate the limits of detection (LOD) of these methods. Using high‐resolution melting (HRM) was used to explore the sensitivity of the dual EvaGreen‐RAA assay. Results The sensitivity of the fluorescent RAA method for detecting SA and LM was 10 copies/μL using plasmids and the sensitivity of the SAMRS‐RAA and EvaGreen‐RAA for detecting SA and LM plasmids was 1 copies/μL. The LOD values of the EvaGreen‐RAA for SA and LM in unenriched simulated milk samples were 100 and 50 CFU/mL, respectively, and the LOD value for both SA and LM using enriched simulated milk samples was 10 CFU/mL. EvaGreen‐RAA had linear amplification in real time in the range of 1–105 copies/μL of the plasmids of SA and LM. The sensitivity of the dual EvaGreen‐RAA assay for SA and LM was estimated to be 102 CFU/mL. Conclusion A real‐time quantitative EvaGreen‐RAA method for detecting SA and LM was developed, which eliminates the need to design complex RAA probes. This dye‐based RAA with SARMS primers provides a new strategy for simplifying fluorescence probe RAA and allowing the detection of multiple pathogens, which has many potential applications.

Cite this record

Zijin Zhao, Yanbo You, Shaowei Hua, Xinxin Shen, Lingjun Li, Xuejun Ma (2024). Dye‐based recombinase‐aided amplification assay with enhanced sensitivity and specificity. iLABMED, 2(4), 294–306. https://doi.org/10.1002/ila2.51

Copy in another style

Zhao, Z., You, Y., Hua, S., Shen, X., Li, L., & Ma, X. (2024). Dye‐based recombinase‐aided amplification assay with enhanced sensitivity and specificity. iLABMED, 2(4), 294–306. https://doi.org/10.1002/ila2.51
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.