We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Physics/Quantifying human gray matter microstructure using neurite exchange imaging (NEXI) and 300 mT/m gradients
PeriodicalsPhysics

Quantifying human gray matter microstructure using neurite exchange imaging (NEXI) and 300 mT/m gradients

Checking your access to this record.

Abstract & Overview

Biophysical models of diffusion tailored to quantify gray matter microstructure are gathering increasing interest. The two-compartment Neurite EXchange Imaging (NEXI) model has been proposed recently to account for neurites, extra-cellular space, and exchange across the cell membrane. NEXI parameter estimation requires multi-shell multi-diffusion time data and has so far only been implemented experimentally on animal data collected on a preclinical magnetic resonance imaging (MRI) set-up. In this work, the translation of NEXI to the human cortex in vivo was achieved using a 3 T Connectom MRI system with 300 mT/m gradients, that enables the acquisition of a broad range of b-values (0 – 7.5 ms/µm²) with a window covering short to intermediate diffusion times (20 – 49 ms) suitable for the characteristic exchange times (10 – 50 ms). Microstructure estimates of four model variants: NEXI, NEXIdot (its extension with the addition of a dot compartment), and their respective versions that correct for the Rician noise floor (NEXIRM and NEXIdot,RM) that particularly impacts high b-value signal, were compared. The reliability of estimates in each model variant was evaluated in synthetic and human in vivo data. In the latter, the intra-subject (scan-rescan) versus between-subjects variability of microstructure estimates was compared in the cortex. The better performance of NEXIRM highlights the importance of correcting for Rician bias in the NEXI model to obtain accurate estimates of microstructure parameters in the human cortex, and the sensitivity of the NEXI framework to individual differences in cortical microstructure. This application of NEXI in humans represents a significant step, unlocking new avenues for studying neurodevelopment, aging, and various neurodegenerative disorders.

Cite this record

Quentin Uhl, Tommaso Pavan, Malwina Molendowska, Derek Kenton Jones, Marco Palombo, Ileana Jelescu (2024). Quantifying human gray matter microstructure using neurite exchange imaging (NEXI) and 300 mT/m gradients. Imaging Neuroscience, 2. https://doi.org/10.1162/imag_a_00104

Copy in another style

Uhl, Q., Pavan, T., Molendowska, M., Jones, D. K., Palombo, M., & Jelescu, I. (2024). Quantifying human gray matter microstructure using neurite exchange imaging (NEXI) and 300 mT/m gradients. Imaging Neuroscience, 2. https://doi.org/10.1162/imag_a_00104
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.