We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Medical Sciences/Optimum Imaging for Parathyroid Localization in Primary Hyperparathyroidism
PeriodicalsMedical Sciences

Optimum Imaging for Parathyroid Localization in Primary Hyperparathyroidism

Checking your access to this record.

Abstract & Overview

The diagnosis of hyperparathyroidism is a biochemical diagnosis. Imaging is never used to diagnose hyperparathyroidism, but only to help localize the offending gland. With the shift in surgical management of primary hyperparathyroidism (PHPT) toward excision of the offending gland alone through a minimally invasive parathyroidectomy (MIP) over the traditional bilateral neck exploration, the importance of accurate localization cannot be overemphasized and is critical for the success of MIP. Generally speaking, if a sestamibi (MIBI) scan and another imaging modality are concordant, then it is safe to go ahead with MIP. However, preoperative localization is complex due to the variable location of parathyroid glands, single versus multiglandular disease, synchronous adenomas, and rarely, parathyroid carcinoma. The current imaging modalities available are ultrasound and 99mTc-MIBI scintigraphy MIBI scans, parathyroid four-dimension computed tomography (4D-CT), positron emission tomography (PET), and magnetic resonance imaging. Selective venous sampling for parathyroid hormone levels in the neck veins is attempted in certain cases of persistent or recurrent PHPT. All the imaging modalities have varied sensitivities and specificities, and this along with their cost and availability is an important consideration of the choice of optimum imaging and developing an algorithmic approach. MIBI scan and ultrasound imaging are the two commonly used first-line imaging techniques for the preoperative location of parathyroid adenomas. Various studies comparing these two report similar sensitivity and specificity for solitary adenomas. The localization accuracy increases when both are combined together as they may provide complimentary information in some cases. SESTAMIBI SCINTIGRAPHY MIBI scintigraphy uses a radioisotope that accumulates in mitochondria and is concentrated in cells with a high metabolic rate, like parathyroid adenoma. It is widely available, relatively inexpensive, and requires less ionizing radiation than a CT scan. Rates of accuracy range from 80% to 95%. Sensitivity may be reduced in small adenomas, adenomas with a predominant cystic component, and adenomas comprising primarily chief cells, and can be confounded by thyroid nodules and multinodular goiters which can also take up the radioisotope and light up. Both false-negative and false-positive scan results are a concern. MIBI-single-photon emission CT (MIBI-SPECT) is a three-dimensional MIBI scan that provides higher-resolution imaging and improves the performance of MIBI scanning. A special advantage of MIBI over ultrasound is in the localization of mediastinal parathyroids or other locations not well imaged on sonography. Lavely et al. reported an accuracy of 86% with the combination of 99mTc-MIBI with SPECT-CT imaging. The advantages are improved anatomic detail over SPECT and two-dimensional planar images alone. It is particularly useful in patients with recurrent PHPT.[1] ULTRASONOGRAM Ultrasound examinations are performed using a variable high-frequency (7.5–11 MHz) linear array transducer. On grayscale ultrasound imaging, parathyroid adenomas classically appear as well-defined ovoid-to-rounded homogenously hypoechoic nodules, located around the thyroid gland, and demarcated from the adjacent thyroid by the thin echogenic thyroid capsule. On color Doppler ultrasound, a polar feeding vessel is typical and highly specific in supporting the diagnosis of parathyroid adenoma. Ultrasound is highly operator dependent. When performed by a dedicated parathyroid sonologist, it may be superior to MIBI scan in localization. Kaur et al., in this context, reported that ultrasound has a higher sensitivity (98%) than MIBI scan (93%) in localizing abnormal parathyroid glands. Moreover, ultrasound had a higher preoperative localization accuracy (93%) than MIBI scan (90%), allowing to choose an appropriate surgical approach.[2] Untch et al. had similar conclusions and also suggested that in cases with inconclusive radionucleotide studies, adding a second modality (mainly ultrasound) can be of value and increase the sensitivity and positive predictive value of the preoperative localization imaging.[3] Singhal et al. reported that using two imaging modalities of MIBI scan and ultrasound, the diagnostic sensitivity is 99% and specificity is 98%.[4] The ultrasound has an added advantage over all other imaging modalities in being able to assess the thyroid gland for any concomitant pathology that may need simultaneous evaluation and intervention. PARATHYROID FOUR-DIMENSIONAL COMPUTED TOMOGRAPHY Parathyroid 4D-CT is a contrast CT-based parathyroid imaging modality termed 4D-CT, with the extra dimension referencing time. 4D-CT relies on the perfusion characteristics of parathyroid adenomas. The rapid uptake and washout of contrast from adenomas are captured through multiple CT passes, resulting in highly detailed, multiplanar images highlighting abnormal parathyroid glands. However, this has a learning curve, and classic imaging characteristics may not be seen in small adenomas making definitive identification challenging.[5] 4D-CT is best avoided or used with caution in the pediatric population due to significant radiation exposure.[6] POSITRON EMISSION TOMOGRAPHY: 18F-FLUOROCHOLINE POSITRON EMISSION TOMOGRAPHY AND 11C-METHIONINE POSITRON EMISSION TOMOGRAPHY Choline PET-CT using choline-based tracers has shown high sensitivity in the detection of hyperfunctioning parathyroid tissue and may replace conventional technetium-99 m- MIBI scintigraphy in the preoperative planning of parathyroid surgery. The additional advantage is its speed, with imaging completed in <15 min as opposed to several hours for MIBI scan, as well as its low radiation dose relative to 4D-CT.[7] A PET-CT hybrid technique using 11C-methionine, which detects increased amino acid metabolism, has also been recently described. Sensitivity approximates standard 99mTc- MIBI scintigraphy (approximately 83%) but has an increased sensitivity for multiglandular disease (67%).[8] 18F-Fluorocholine PET has superior performance in terms of sensitivity, while both the two tracers (18F-fluorocholine PET and 11C-methionine PET) have comparable accuracy in terms of positive predictive value.[9] MAGNETIC RESONANCE IMAGING Magnetic resonance (MR) with gadolinium contrast has a low sensitivity of 43%–71%. The main advantages of MR are the lack of radiation, detailed anatomical information, and the ability to widely evaluate ectopic glands. MR is used as an adjunct in re-operative cases and in those with negative or discordant localization studies.[10] Currently, MR role is use is quite infrequent the use of MRI for parathyroid localization is quite infrequent and restricted to a few centers. Scattergood et al. reported that the combination of ultrasound and MIBI scintigraphy provides the highest sensitivity of preoperative localization. Where preoperative localization is not achieved with ultrasound or MIBI scintigraphy, 4D-CT adds little additional benefit. In this setting, other modalities of localization such as choline PET, selective venous sampling, intraoperative methylene blue, or intraoperative parathyroid hormone levels could be considered.[11] Currently, no evidence-based guidelines are available for the optimal imaging strategy, and there is a lack of consensus on the optimal diagnostic imaging algorithm. While most institutions use a combination of US and MIBI[12,13] as the first-line imaging, an increasing number of centers have adopted 4D-CT and choline PET-CT in recent years.[14] Surgeon-performed preoperative ultrasound is a useful adjunct in improving localization.[15] Variability in imaging preferences exists because it is not the modality that has the greater impact but the local expertise that determines accuracy to a larger degree. Most institutions are driven by their experience, traditions, available skills, and cost. With no clear winner, it's a case of "what works best for you." Disclosure This material has never been published and is not currently under evaluation in any other peer-reviewed publication. Ethical approval Not applicable. Informed consent Not applicable.

Cite this record

Alka Ashmita Singhal (2023). Optimum Imaging for Parathyroid Localization in Primary Hyperparathyroidism. Journal of Head & Neck Physicians and Surgeons, 11(2), 71–73. https://doi.org/10.4103/jhnps.jhnps_64_23

Copy in another style

Singhal, A. A. (2023). Optimum Imaging for Parathyroid Localization in Primary Hyperparathyroidism. Journal of Head & Neck Physicians and Surgeons, 11(2), 71–73. https://doi.org/10.4103/jhnps.jhnps_64_23
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.