We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Medical Sciences/A dosimetric comparison of volumetric modulated arc therapy with three-dimensional conformal radiotherapy in the treatment of cervical cancer
PeriodicalsMedical Sciences

A dosimetric comparison of volumetric modulated arc therapy with three-dimensional conformal radiotherapy in the treatment of cervical cancer

Checking your access to this record.

Abstract & Overview

Background: External beam radiotherapy (EBRT) is essential in the management of locally advanced cervical cancer (LACC). Volumetric modulated arc therapy (VMAT) is thought to achieve higher conformity to the planned target volume (PTV) and better sparing of organs at risk (OAR) when compared to three-dimensional conformal radiotherapy (3D-CRT). This study focused on these principles as it applied to treatment and potential toxicity in the management of LACC. Aim: The aim of this study was to compare dosimetric parameters between VMAT and 3D-CRT in the management of LACC. Setting: The study analysed patients treated at Groote Schuur Hospital (GSH) between May and December 2017. Methods: This is a non-randomised comparative retrospective study. Three-dimensional conformal radiation and VMAT plans were generated, and data on treatment parameters for PTV D50%, Dmax, Dmean, conformity index (CI), homogeneity index (HI), treated volume (TV), irradiated volume (IV) and OAR constraints; femoral heads, bladder, bowel bag, rectum and bone marrow were collected. Results: Of the 45 patients assessed, VMAT showed statistically significant, lower treatment parameter values for CI (1.09 vs. 1.49) and TV (1613.1 cm 3 vs. 2230.3 cm 3 ), whereas 3D-CRT showed lower Dmax (48.1 Gy vs. 49.2 Gy) and IV (10652.2 cm 3 vs. 14618.1 cm 3 ). Volumetric modulated arc therapy OAR doses revealed a lower V45 for bowel bag (182.3 cm 3 vs. 411.3 cm 3 ; p < 0.001), lower V40 for bone marrow (19.1% vs. 38.7%; p < 0.001) and rectum (88.5% vs. 96%; p < 0.001). A reduced 3D-CRT dose was noted for bladder Dmax (47.4 Gy vs. 48.3 Gy; p < 0.001). Conclusion: Volumetric modulated arc therapy offered a superior dosimetric option, with better OAR dose sparing and optimal tumour dosimetry.

Cite this record

Visham Bhagaloo, Nazreen Bhim, Alistair Hunter, Nazia Fakie (2021). A dosimetric comparison of volumetric modulated arc therapy with three-dimensional conformal radiotherapy in the treatment of cervical cancer. South African Journal of Oncology, 5. https://doi.org/10.4102/sajo.v5i0.149

Copy in another style

Bhagaloo, V., Bhim, N., Hunter, A., & Fakie, N. (2021). A dosimetric comparison of volumetric modulated arc therapy with three-dimensional conformal radiotherapy in the treatment of cervical cancer. South African Journal of Oncology, 5. https://doi.org/10.4102/sajo.v5i0.149
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.