Background Multiple studies have reported an unacceptable implant-related complication rate in proximal humeral fractures treated with locking plates, particularly in older patients. Our objective was to compare the fracture fixation failure rates in elderly patients, after a dedicated technique for locking plate fixation with cement augmentation or without it. Methods A total of 168 open reduction and internal fixation with locking plates were performed for complex proximal humerus fractures by a single surgeon in 136 women and 32 men older than 65 years of age (average 76 years). Treatment groups included group 1 with noncemented screws (n = 90) and group 2 with cemented screws (n = 78). As per Mayo-FJD Classification, there were 74 (44%) varus posteromedial impaction, 41 (24%) algus impaction, 46 (28%) surgical neck, and 7 (4%) head dislocation injuries. A retrospective radiographic and a clinical analysis was performed. Results At a mean follow-up of 33 months, the implant failure rate was significantly lower in the cement augmentation group (1% vs. 8%, P = .03). The overall complication rate was 21% (25% group 1, 15% group 2; P = .1). Global avascular necrosis was associated with sustaining a valgus impacted fracture ( P = .02 odds ratio 5.7), but not to augmentation. Partial avascular necrosis occurred only in patients treated with cemented screws (3.8%). The overall revision rate was 9% in both groups. Forward elevation was 126 ± 36 degrees and external rotation was 44 ± 19 degrees. The mean Constant score was 70 ± 15 in group 1 and 76 ± 15 in group 2 ( P = .03). Conclusion Cement augmentation significantly decreased the rate of implant failure. Good results are expected for most patients treated with this technique.

Cite this record

Antonio M. Foruria, Natalia Martínez‐Catalán, María Valencia, Diana Morcillo, Emílio Calvo (2021). Proximal humeral fracture locking plate fixation with anatomic reduction, and a short-and-cemented-screws configuration, dramatically reduces the implant related failure rate in elderly patients. JSES International, 5(6), 992–1000. https://doi.org/10.1016/j.jseint.2021.06.004

Copy in another style

Foruria, A. M., Martínez‐Catalán, N., Valencia, M., Morcillo, D., & Calvo, E. (2021). Proximal humeral fracture locking plate fixation with anatomic reduction, and a short-and-cemented-screws configuration, dramatically reduces the implant related failure rate in elderly patients. JSES International, 5(6), 992–1000. https://doi.org/10.1016/j.jseint.2021.06.004
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.