We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Electronics & Telecommunication Engineering/Real-time power loss optimized operation of a solid state transformer by utilizing the common-mode voltage
PeriodicalsElectronics & Telecommunication Engineering

Real-time power loss optimized operation of a solid state transformer by utilizing the common-mode voltage

Checking your access to this record.

Abstract & Overview

This article presents a general methodology and a real-time capable, analytically solvable model for minimizing the total power losses of a modular Solid-State Transformer (SST). The approach leverages the inherent Degree of Freedom (DoF) offered by the common-mode (CM) voltage u cm in three-phase systems. By systematically adjusting the CM voltage, the power distribution among all sub-modules (SM) is influenced to reduce the total losses of the Dual Active Bridges (DAB) without imposing additional constraints on the SST operation. An analytical loss model, with the CM voltage as the DoF, is derived from measured loss characteristics of an individual DAB module and extrapolated to the full three-phase SST. The proposed optimization method is implemented on a field-programmable gate array which is able to find the global loss minimum in real time. A 45 kW, 400 V AC to 750 V DC SST test bench is used to validate the methodology. The calculated and measured results over the whole power range of the prototype align which confirms the accuracy of the loss model. An overall loss reduction of up to 20% is achieved without sacrificing output voltage quality or requiring changes to the modulation scheme.

Cite this record

Tobias Merz, Nikolas Menger, Max-Emanuel Siegemund, Rüdiger Schwendemann, Marc Hiller (2025). Real-time power loss optimized operation of a solid state transformer by utilizing the common-mode voltage. Power Electronic Devices and Components, 12, 100125–100125. https://doi.org/10.1016/j.pedc.2025.100125

Copy in another style

Merz, T., Menger, N., Siegemund, M., Schwendemann, R., & Hiller, M. (2025). Real-time power loss optimized operation of a solid state transformer by utilizing the common-mode voltage. Power Electronic Devices and Components, 12, 100125–100125. https://doi.org/10.1016/j.pedc.2025.100125
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.