We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Civil & Construction Engineering/Thermal insulation performance of non-load-bearing light gauge slotted steel stud walls
PeriodicalsCivil & Construction Engineering

Thermal insulation performance of non-load-bearing light gauge slotted steel stud walls

Checking your access to this record.

Abstract & Overview

Light gauge steel stud walls have been widely used in buildings as load-bearing members. But if used as non-load-bearing walls, more rows of perforations can be placed on stud webs and then the thermal bridge effect can be reduced. Experiments on six non-load-bearing light gauge slotted steel stud walls were conducted using a calibrated hot box. The temperatures of the steel studs and gypsum plasterboard were monitored for subsequent analysis of thermal bridging. The effects of parameters (number of rows of perforations, stud web height, and the ratio of window area to wall area) on the insulating capacity of the wall were identified and analyzed. Thermal transmittance decreases by 18.5% and 29.6% for specimens with 3 and 7 rows of perforations in comparison with the specimen without perforations, while it decreases by 29.8% and 42.7% respectively for 150 mm and 200 mm thick walls compared with that of the 100 mm thick wall. However, thermal transmittance increases obviously for the wall with a window opening relative to the wall without a window opening, reaching 14.7% in this test since more studs are placed around the window opening. A three-dimensional finite element (FE) model of the wall was developed and validated against experimental results, and then was used for parametric studies. A general method of calculating the thermal transmittance of the light gauge slotted steel stud wall was suggested based on the experiment and the FE model results, which can consider influences of wall thickness, web perforations, window openings, and thermal properties of materials.

Cite this record

Yuyin Wang, Faqi Liu, Hua Yang, Feng Fu, Yuteng Yan (2024). Thermal insulation performance of non-load-bearing light gauge slotted steel stud walls. Sustainable Structures, 4(1). https://doi.org/10.54113/j.sust.2024.000042

Copy in another style

Wang, Y., Liu, F., Yang, H., Fu, F., & Yan, Y. (2024). Thermal insulation performance of non-load-bearing light gauge slotted steel stud walls. Sustainable Structures, 4(1). https://doi.org/10.54113/j.sust.2024.000042
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.