Abstract & Overview
Electromagnetic compatibility(EMC) is not only an important technique request during the development of electronic electric energy meters,but also one of the important paraenergy meters to judge electric energy meters can run safely and dependably.This paper firstly introduces several common-mode interferences,and then analyzes the cause of electromagnetic interference source and the influencing mechanism of electronic electric energy meters performance,finally put forward several EMI technologies including choice of and optimization design of circuit which effectively advance anti-jamming capability.The application of EMI technologies ensures electric energy meters run steadily and measure accurately in electrical grid,consequently provides theories basis for the strengthen of measurement management in electric power company.