We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Medical Sciences/Reliability of ultrasound measurements of quadriceps muscle thickness in critically ill patients
PeriodicalsMedical Sciences

Reliability of ultrasound measurements of quadriceps muscle thickness in critically ill patients

Checking your access to this record.

Abstract & Overview

BACKGROUND: Muscle wasting in critically ill patients is associated with negative clinical outcomes. Ultrasound quadriceps femoris muscle assessment may constitute a convenient tool to evaluate muscle wasting. Nevertheless, its reliability remains uncertain. Our primary aim was to study the intra- and inter-observer reliability of this technique. Our secondary aim was to assess the evolution of the quadriceps muscle during the first 3 weeks after ICU admission and its possible association with nutritional intake. METHODS: This observational study included patients expected to stay more than 7 days in the ICU. Ultrasound quadriceps muscle thickness was measured with a 12 MHz linear transducer, by two trained physicians, on D1, D3, D5, D7 and D21. Two measurements sites were evaluated: on the midpoint or on the two-thirds of the length between the anterior superior iliac spine and the upper border of the patella. Intra and inter-observer reliability was assessed by calculating the intra-class correlation coefficient (ICC). RESULTS: A total of 280 ultrasound quadriceps thickness measurements were performed on 29 critically ill patients. Intra-observer reliability's ICC was 0.74 [95% CI 0.63; 0.84] at the "midpoint" site and 0.83 [95% CI 0.75; 0.9] at the "two-thirds" site. Inter-observer reliability's ICC was 0.76 [95% CI, 0.66; 0.86] at the "midpoint" site and 0.81 [95% CI, 0.7; 0.9] at the "two-thirds" site. Quadriceps femoris muscle thickness decreased over 16% within the first week after ICU admission. No correlation was found between muscle loss and caloric (p = 0.96) or protein (p = 0.80) debt over the first week. CONCLUSION: The assessment by ultrasonography of the quadriceps muscle thickness reveals good intra- and inter-observer reliability and may constitute a promising tool to evaluate the effect of nutritional-based interventions on muscle wasting in critically ill patients. TRIAL REGISTRATION: "Committee for the Protection of Human Subjects in Biomedical Research" - Paris Ile de France VI Pitié-Salpêtrière - 10/07/2014. French Data Protection Committee ("Commission Nationale Informatique et Libertés") - #1771144.

Cite this record

Emmanuel Pardo, Hanen El Behi, Priscilla Boizeau, Franck Verdonk, Corinne Alberti, Thomas Lescot (2018). Reliability of ultrasound measurements of quadriceps muscle thickness in critically ill patients. BMC Anesthesiology, 18(1), 205–205. https://doi.org/10.1186/s12871-018-0647-9

Copy in another style

Pardo, E., Behi, H. E., Boizeau, P., Verdonk, F., Alberti, C., & Lescot, T. (2018). Reliability of ultrasound measurements of quadriceps muscle thickness in critically ill patients. BMC Anesthesiology, 18(1), 205–205. https://doi.org/10.1186/s12871-018-0647-9
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.