We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Pharmacy/Ac-225 radiochemistry through the lens of [225Ac]Ac-DOTA-TATE

Checking your access to this record.

Abstract & Overview

BACKGROUND: Targeted alpha therapy with Ac-225 showed to be effective in treating metastatic cancers. However, the complex decay chain requires optimized radiolabeling and quality control. This study aims to determine critical parameters and establish optimal labeling and accurate measuring techniques for radiochemical yield and purity with DOTA-TATE as a model molecule. Ac-225 sources were analyzed for metals (ΣFe, Zn, Cu) and quantified by UPLC. Optimization of radiolabeling kinetics for clinical conditions was performed in regards to temperature (20-90 °C), heating time (5-60 min), pH (2.5-10, with/without excess of metal ions), buffers, quenchers, volume (0.1-10 mL) and molar activity (90-540 kBq/nmol). The quality control was investigated using radio-TLC/HPLC by changing gradient to evaluate peak separation, radiolysed peptide and impurity separation. RESULTS: Metal ingrowth was observed in Ac-225 stocks (n = 3), (time of arrival: 17.9, 36.8 and 101.4 nmol per 10 MBq). Optimal radiochemical yields were achieved with > 80 °C (20 min) at pH 8.5 (15 mM TRIS) up to 270 kBq. Labeling at a high pH showed a higher RCY, even in presence of an excess of metals. High stability (RCP > 90%) was achieved after addition of quenchers (cysteine, methionine, ascorbate, histidine, or gentisic acid (35 mM)) up to 24 h. For optimal determination of the radiochemical purity (indirect HPLC) fifty fractions are required. CONCLUSION: The quality of Ac-225 labeled DOTA-radiopharmaceuticals is highly dependent on the pH and stabilization (buffer/quencher). Within this research it is demonstrated that optimized quality control methods and accurate measurement of the radiolabeling kinetics are crucial to ensure safe implementation for patient treatment.

Cite this record

Eline L. Hooijman, Jan R. de Jong, Carolline Ntihabose, Frank Bruchertseifer, Alfred Morgenstern, Yann Seimbille, et al. (2025). Ac-225 radiochemistry through the lens of [225Ac]Ac-DOTA-TATE. EJNMMI Radiopharmacy and Chemistry, 10(1), 9–9. https://doi.org/10.1186/s41181-025-00332-z

Copy in another style

Hooijman, E. L., Jong, J. R. D., Ntihabose, C., Bruchertseifer, F., Morgenstern, A., Seimbille, Y., Brabander, T., Koolen, S. L., & Blois, E. D. (2025). Ac-225 radiochemistry through the lens of [225Ac]Ac-DOTA-TATE. EJNMMI Radiopharmacy and Chemistry, 10(1), 9–9. https://doi.org/10.1186/s41181-025-00332-z
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.