We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Civil & Construction Engineering/Evaluation of biological and physico-chemical quality of public swimming pools, Hamadan (Iran)
PeriodicalsCivil & Construction Engineering

Evaluation of biological and physico-chemical quality of public swimming pools, Hamadan (Iran)

Checking your access to this record.

Abstract & Overview

Aims: The purpose of this study was to determine the types of fungal contamination and evaluation the fecal Streptococcus, total coliform and some physical and chemical parameters of swimming pool waters in Hamadan (Iran) Materials and Methods: In this study, biological and physico-chemical quality were evaluated. Bacterial and fungal contamination of four public indoor swimming pools was evaluated by standard total coliforms fermentation and using membrane filtration and carpet and swab sampling method with a month interval. In addition, physical and chemical parameters such as residual chlorine, temperature and pH were measured. Results: Results showed that the mean water temperature pH and residual chlorine were 29.3±1.3, 7.38±0.5 and 0.84±0.5 mg/L, respectively. Mean of total coliform was 1.8±7.7 MPN/100ml and its maximum and minimum were 43 and 0 MPN/100ml, respectively. Mean of fecal streptococcus was 0.3±1.6 MPN/100ml and its maximum and minimum were 9 and 9 MPN/100ml, respectively. In the environment of pools, fungi were isolated in order of Cladosporium spp., Penicillium spp., Aspergillus spp., Alternaria spp., Aspergillus.niger spp., Rhodotorula spp and Phoma spp. In the collected water sample, no fungal growths were seen. In the studied pools, the microbial and fungi contamination showed significant and insignificant difference, respectively.Conclusion: As results showed the residual chlorine in pools water was lower than standard level and as regard to microbial contamination in pool water, it can be concluded that the disinfection system has been impaired.

Cite this record

Ali Toolabi, Edris Hoseinzadeh, Mohammadi Farshid, Reza Shokouhi, Seyed Amir Ghiasian, Ghodratollah Roshanaie, et al. (2013). Evaluation of biological and physico-chemical quality of public swimming pools, Hamadan (Iran). International Journal of Environmental Health Engineering, 2(1), 21–21. https://doi.org/10.4103/2277-9183.113207

Copy in another style

Toolabi, A., Hoseinzadeh, E., Farshid, M., Shokouhi, R., Ghiasian, S. A., Roshanaie, G., & Azizi, S. (2013). Evaluation of biological and physico-chemical quality of public swimming pools, Hamadan (Iran). International Journal of Environmental Health Engineering, 2(1), 21–21. https://doi.org/10.4103/2277-9183.113207
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.