Abstract & Overview

Objectives: Lipemia poses a significant preanalytical problem for complete blood count (CBC) measurement due to limited and non-standardized methods for recognition and removal. We aimed to verify the optical hemoglobin (Hb-O) measurements on the Sysmex XN-1000 hematology analyzer (HA) as a possible reliable method for managing lipemic CBC samples. Methods: /10 min). Plasma was carefully removed, and Hb concentration was measured. The values obtained from the lipemic samples were adjusted according to the measurements in the plasma. The removed plasma was substituted with the analyzer's diluent, and measurements were repeated. Triglyceride concentrations were measured in lipemic plasma samples. Results: Hb-O showed statistically insignificant and acceptable bias compared to the initial Hb measurement according to the strictest acceptability criteria (-0.4 %, 95 % CI: -1.2-0.3, p=0.2447). The observed bias did not correlate with the degree of lipemia (rho=-0.072, 95 % CI: -0.295 to 0.157, p=0.537). Hemoglobin measured in samples with lipemic plasma replaced by analyzer diluent exhibited minimal, albeit statistically significant, bias (-1.1 %, 95 % CI: -2.0 to (-0.1), p=0.025). The observed bias negatively correlated with the degree of lipemia (rho=-0.369, 95 % CI: -0.550 to (-0.155), p=0.001). The highest unacceptable bias was found in the recalculated hemoglobin values based on the measured plasma hemoglobin (-3.5 %, 95 % CI: -4.1 to (-2.9), p<0.0001). Conclusions: Hb-O measurement is the most reliable measure of lipemia removal in CBC samples on the Sysmex XN-1000 HA.

Cite this record

Vanja Radišić Biljak, Lucija Dolovčak, Iva Bakarić, Ana Nikler, Andrea Saračević, Marija Grdić Rajković (2025). How to handle lipemic CBC samples on Sysmex hematology analyzers?. Advances in Laboratory Medicine / Avances en Medicina de Laboratorio, 6(2), 166–172. https://doi.org/10.1515/almed-2024-0206

Copy in another style

Biljak, V. R., Dolovčak, L., Bakarić, I., Nikler, A., Saračević, A., & Rajković, M. G. (2025). How to handle lipemic CBC samples on Sysmex hematology analyzers? Advances in Laboratory Medicine / Avances en Medicina de Laboratorio, 6(2), 166–172. https://doi.org/10.1515/almed-2024-0206
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.