We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Electrical Engineering/Effect of the DC link Parameters on Transient Peaks and Harmonics Generated due to Grid Faults in Wind-Driven DFIG
PeriodicalsElectrical Engineering

Effect of the DC link Parameters on Transient Peaks and Harmonics Generated due to Grid Faults in Wind-Driven DFIG

Checking your access to this record.

Abstract & Overview

In this paper, the effect of the DC link capacitor (Cd), and DC link inductor (Ld), on the performance of the grid-connected, wind-driven, Double-Fed Induction generator (DFIG) is investigated during 3-phase symmetrical grid-voltage faults. The DFIG system is modelled using Matlab/Simulink software, and simulation results are plotted against Cd and Ld for each of the three considered grid faults. The transient peaks of the stator current, rotor current, rotor voltage, and DC link current and voltage, due to grid voltage sag, grid voltage swell, and the 3-phase-to-ground fault at different values of Cd and Ld are presented. The current and voltage harmonics generated due to grid faults at different Cd and Ld values are also investigated. The time taken by the DFIG currents and voltages to reach their steady state is calculated, for the 3-phase ground fault, as a function of DC link parameters. Investigating the responses of stator and rotor currents, rotor voltage, and DC-link voltage and current at different values of Cd and Ld lead to conclude the optimum values of the DC-link parameters that lead to fast fault recovery.

Cite this record

Mona N. Eskander, Sanaa M I Amer (2025). Effect of the DC link Parameters on Transient Peaks and Harmonics Generated due to Grid Faults in Wind-Driven DFIG. International Journal of Electrical Engineering and Computer Science, 7, 8–16. https://doi.org/10.37394/232027.2025.7.2

Copy in another style

Eskander, M. N., & Amer, S. M. I. (2025). Effect of the DC link Parameters on Transient Peaks and Harmonics Generated due to Grid Faults in Wind-Driven DFIG. International Journal of Electrical Engineering and Computer Science, 7, 8–16. https://doi.org/10.37394/232027.2025.7.2
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.