Home/e-Resources/Computer Science & Information Technology/Influence of Convolution Kernel and Beam-Hardening Effect on the Assessment of Trabecular Bone Mineral Density Using Quantitative Computed Tomography
PeriodicalsComputer Science & Information Technology

Influence of Convolution Kernel and Beam-Hardening Effect on the Assessment of Trabecular Bone Mineral Density Using Quantitative Computed Tomography

Checking your access to this record.

Abstract & Overview

➮!"✳ $%&%'✳ ()✲'%✳ ❮,"✳ -.&✳ $.&✳ ❒%'.0%'12%✳ ❒.3%)12%✳ ➮)4,&0%'12%✳ ✷✵✷✵✳ 7✳ ✷✵✱ "9:✳ ✷ the effect of various convolution kernels, beam-hardening effect, as well as other CT scanner settings for Hounsfield units.In this work, we studied samples of trabecular bone tissue of the femoral heads and calibrated samples of an aqueous solution of dipotassium hydrogen phosphate with known mineral density.Trabecular bone tissue samples of the femoral heads and calibrated samples of an aqueous solution of dipotassium hydrogen phosphate with known mineral density were scanned on Toshiba Aquilion 64 scanner.The samples were scanned in various modes: at different tube currents, "in the air" and inside the calibration phantom.The resulting images processed by the FC17 and FC03 convolution kernels were analyzed.It was shown that tube current magnitude practically does not affect the Hounsfield units.Different convolution kernels demonstrate significantly different Hounsfield units when scanning the same samples "in the air".It has been confirmed that the beam-hardening effect significantly affects the Hounsfield units and should be considered when evaluating bone mineral density.No differences were found in measurements "in the air' and in the phantom at a significance level of 5% for the FC03 kernel, which confirms the fact that FC03 is intended to correct the beam-hardening effect.An ambiguous relationship was noted between the Hounsfield units and the mineral density for low-density samples when scanned with the FC03 kernel.FC17 kernel, in comparison with FC03, is considered more preferable and suitable for assessing bone mineral density.However, pre-calibration with phantom is required for a wide range of preset mineral densities.Regression dependencies were obtained for recalculation of Hounsfield units from experiments "in the air" to Hounsfield units of the same samples scanned in surrounding tissues (in the phantom).

Cite this record

Dmitriy V. Ivanov, Author, Leonid Yu. Kossovich, Leonid V. Bessonov, Alexey Vladimirovich Petraikin, Aleksandr Dol, et al. (2020). Influence of Convolution Kernel and Beam-Hardening Effect on the Assessment of Trabecular Bone Mineral Density Using Quantitative Computed Tomography. Izvestiya of Saratov University Mathematics Mechanics Informatics, 20(2), 205–219. https://doi.org/10.18500/1816-9791-2020-20-2-205-219

Copy in another style

Ivanov, D. V., Author, Kossovich, L. Y., Bessonov, L. V., Petraikin, A. V., Dol, A., Akhmad, E. S., Morozov, S. P., & Vladzymyrskyy, A. V. (2020). Influence of Convolution Kernel and Beam-Hardening Effect on the Assessment of Trabecular Bone Mineral Density Using Quantitative Computed Tomography. Izvestiya of Saratov University Mathematics Mechanics Informatics, 20(2), 205–219. https://doi.org/10.18500/1816-9791-2020-20-2-205-219