Abstract & Overview
Non-intrusive load monitoring (NILM) acquires power consumption information in low cost. It can realize household load recognition and decomposition without affecting the normal power consumption. The installation of smart meters also provides data and technical support for NILM. Firstly, by researching power characteristics, current waveforms and harmonic characteristics of common household appliances, principal component analysis (PCA) is used to reduce the dimension of high-dimensional harmonic feature space and extract the main harmonic information. It is combined with basic power characteristics to form multi-feature objective function. Then, on the basis of integer linear programming (ILP) model, NILM method of PCA-ILP considering multi-feature objective function is established to realize load decomposition and recognition for different electrical appliances. Finally, case study indicates that the proposed method has a sound performance for load decomposition in different scenarios of household appliances under different signal-to-noise ratio (SNR).