Abstract & Overview
Gypsum type III is commonly used for working models and as a tool for restorations or dentures manufacturing in the laboratory. K 2 SO 4 solution is recommended to be added to gypsum type III because it can accelerate the setting time. The aim of this study was to identify the effects of a K2SO4 solution on the surface hardness of gypsum type III. The surface hardness was tested using a Vickers Hardness Tester with a load of 500 gf. The results were analyzed using a one-way ANOVA. The surface hardness of gypsum type III manipulated using a 1.5% K 2 SO 4 solution was higher than the surface hardness of gypsum type III manipulated without K 2 SO 4 but lower than the surface hardness of gypsum type IV. Therefore, the use of a 1.5% K2SO4 solution can increase the hardness of gypsum type III but not enough to make it equivalent to the surface hardness of gypsum type IV.