We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Artificial Intelligence & Machine Learning/Test-retest reproducibility of atomic force microscopy measurements of human trabecular meshwork stiffness
PeriodicalsArtificial Intelligence & Machine Learning

Test-retest reproducibility of atomic force microscopy measurements of human trabecular meshwork stiffness

Checking your access to this record.

Abstract & Overview

Purpose: The purpose of the present study was to quantify test-retest reproducibility of measurements of stiffness of the human trabecular meshwork (HTM) by atomic force microscopy (AFM). Methods: Eleven 40 μm radial limbal cryostat sections from a fresh human donor rim were mounted on charged slides and rehydrated at room temperature. Stiffness at four TM locations (anterior to posterior along Schlemm’s canal) was measured by AFM. At each location, a 6 x 6 grid was sampled. Indentation points were evenly distributed over a 20 μm x 20 μm area, with a rate of one load/unload cycle per second. Measurements were then repeated for calculation of test-retest variability. Results: The test-retest coefficients of variation for the four measurement locations (anterior to posterior) were 24.39, 25.28, 12.74, and 14.26%, respectively, with a notable drop in the two posterior locations compared to the anterior. The test-retest coefficient for the sections was 19.17%. For the entire eye, the test-retest coefficient of variation for the measurement of the TM stiffness was 17.13%. Young’s moduli consistently decreased from anterior to posterior location. Conclusions: Wide regional variation suggests that single value does little to fully describe the complex array of TM stiffness levels within the eye, and future studies of TM stiffness assessed by AFM should include multiple tissue samples from each eye, with documentation of the anterior-posterior location of each measurement.

Cite this record

Larry E. Kagemann, Joe E. Candiello, Gadi Wollstein, Hiroshi Ishikawa, Richard A. Bilonick, Ian A. Sigal, et al. (2020). Test-retest reproducibility of atomic force microscopy measurements of human trabecular meshwork stiffness. Modeling and Artificial Intelligence in Ophthalmology, 2(4), 34–43. https://doi.org/10.35119/maio.v2i4.107

Copy in another style

Kagemann, L. E., Candiello, J. E., Wollstein, G., Ishikawa, H., Bilonick, R. A., Sigal, I. A., Jonescu-Cuypers, C. P., Kumta, P. N., & Schuman, J. S. (2020). Test-retest reproducibility of atomic force microscopy measurements of human trabecular meshwork stiffness. Modeling and Artificial Intelligence in Ophthalmology, 2(4), 34–43. https://doi.org/10.35119/maio.v2i4.107
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.