Abstract & Overview
This study was conducted in 8.2m wide single-span greenhouse to investigate the effect of presence or absence of rafter steel pipe joint and foundation conditions on greenhouse structural performance.Structural performance was evaluated by static loading test using the structural performance evaluation system for single-span greenhouse.The measured displacement was compared with the predicted result by numerical analysis.The displacement of each measurement location showed a significant difference regardless of the conditions of the foundation and presence or absence of rafter steel pipe joint.Compared to the hinge conditions, the difference in structural performance of the greenhouse in the fixed conditions was seen to be relatively large.The difference in structural performance according to presence or absence of rafter steel pipe joints, the lateral stiffness of the joint was 8.1% greater.