We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Dentistry/Post-curing protocols and dimensional accuracy of 3D-printed resin materials
PeriodicalsDentistry

Post-curing protocols and dimensional accuracy of 3D-printed resin materials

Checking your access to this record.

Abstract & Overview

Purpose The study aims to evaluate the influence of various post-curing times and temperatures on the dimensional accuracy of 3D-printed resin space maintainers.Materials and Methods Using biocompatible printing resins, the study designed band samples of space maintainers, which were 3D printed with the SLA printer. Samples were grouped based on thickness (0.5 mm and 1.0 mm) and post-cured under different conditions of temperature and time (60°C-30 minutes, 60°C-90 minutes, 60°C-120 minutes, 60°C-60 minutes, 40°C-60 minutes, 80°C-60 minutes). The accuracy of the band part of the printed maintainers was analysed using the total and 4 comparison points’ arithmetic mean of the surface deviation on the band’s surface.Results The study revealed that the post-curing conditions notably influenced the dimensional accuracy of the printed samples. Post-curing temperature and duration variations produced significant differences in dimensional stability between the groups. Particularly, a post-curing period of 60°C for 60 minutes was identified as optimal for achieving better dimensional accuracy, especially for samples with 1.0 mm thickness.Conclusions Different post-curing parameters significantly affect the dimensional accuracy of 3D-printed resin space maintainers. The 1.0 mm band thickness and a 60°C and 60 minutes post-curing protocol optimize the accuracy of the maintainers.

Cite this record

Merve Aksoy, Kübra Gülnur Topsakal, Yağızalp Sükut, Gökhan Serhat Duran (2025). Post-curing protocols and dimensional accuracy of 3D-printed resin materials. Clinical and Investigative Orthodontics, 84(3), 174–181. https://doi.org/10.1080/27705781.2025.2512265

Copy in another style

Aksoy, M., Topsakal, K. G., Sükut, Y., & Duran, G. S. (2025). Post-curing protocols and dimensional accuracy of 3D-printed resin materials. Clinical and Investigative Orthodontics, 84(3), 174–181. https://doi.org/10.1080/27705781.2025.2512265
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.