We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Biomedical Engineering/Influence of wall thickness on fluid–structure interaction computations of cerebral aneurysms
PeriodicalsBiomedical Engineering

Influence of wall thickness on fluid–structure interaction computations of cerebral aneurysms

Checking your access to this record.

Abstract & Overview

Fluid–structure interaction (FSI) analyses of cerebral aneurysm using patient‐specific geometry with uniform and pathological aneurysmal wall thickness models are carried out. The objective is to assess the influence of the wall thickness on the FSI and hemodynamics in aneurysms. Two aneurysm models that were reconstructured based on CT images are used. The arterial wall thickness is set to 0.3 mm for the non‐aneurysmal artery and to 0.05 mm for the aneurysmal wall based on experimental findings. Another set of aneurysm models with a uniform wall thickness of 0.3 mm for the entire model is used for comparison. The FSI simulations are carried out using the deforming‐spatial‐domain/stabilized space–time method with physiological inflow and pressure profiles. Computations with different aneurysmal wall thicknesses depict considerable differences in displacement, flow velocity and wall shear stress (WSS). The wall displacement for the pathological wall model is 61% larger than that of the uniform wall model. Consequently, the flow velocities in the aneurysm with the pathological wall model are lower, and that results in a 51% reduction in WSS on the aneurismal wall. Because low WSS on the aneurymal wall is linked to growth and rupture risk of aneurysm, the results suggest that using uniform wall thickness for the aneurysmal wall could underestimate risk in aneurysms. Copyright © 2009 John Wiley & Sons, Ltd.

Cite this record

Ryo Torii, M. Oshima, Toshio Kobayashi, Kiyoshi Takagi, Tayfun E. Tezduyar (2009). Influence of wall thickness on fluid–structure interaction computations of cerebral aneurysms. International Journal for Numerical Methods in Biomedical Engineering, 26(3-4), 336–347. https://doi.org/10.1002/cnm.1289

Copy in another style

Torii, R., Oshima, M., Kobayashi, T., Takagi, K., & Tezduyar, T. E. (2009). Influence of wall thickness on fluid–structure interaction computations of cerebral aneurysms. International Journal for Numerical Methods in Biomedical Engineering, 26(3-4), 336–347. https://doi.org/10.1002/cnm.1289
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.