Abstract & Overview
In order to realize the coordination problem of the robot application system and realize the com-munication between multiple control modules, a distributed control communication protocol based on UART is designed and implemented. On the hardware, the RS-485 type electrical interface is used to analyze the information model of the control network. The real-time information scheduling algorithm of the token ring control field bus is designed. The communication protocol uses token ring principle to schedule each control module in real time, so as to realize the distributed field control based on UART.