We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Physics/Extraocular muscle sampled volume in Graves’ orbitopathy using 3-T fast spin-echo MRI with iterative decomposition of water and fat sequences
PeriodicalsPhysics

Extraocular muscle sampled volume in Graves’ orbitopathy using 3-T fast spin-echo MRI with iterative decomposition of water and fat sequences

Checking your access to this record.

Abstract & Overview

BACKGROUND: Current magnetic resonance imaging (MRI) techniques for measuring extraocular muscle (EOM) volume enlargement are not ideally suited for routine follow-up of Graves' ophthalmopathy (GO) because the difficulty of segmenting the muscles at the tendon insertion complicates and lengthens the study protocol. PURPOSE: To measure the EOM sampled volume (SV) and assess its correlation with proptosis. MATERIAL AND METHODS: A total of 37 patients with newly diagnosed GO underwent 3-T MRI scanning with iterative decomposition of water and fat (IDEAL) sequences with and without contrast enhancement. In each patient, the three largest contiguous coronal cross-sectional areas (CSA) on the EOM slices were segmented using a polygon selection tool and then summed to compute the EOM-SV. Proptosis was evaluated with the Hertel index (HI). The relationships between the HI value and EOM-SV and between HI and EOM-CSA were compared and assessed with Pearson's correlation coefficient and the univariate regression coefficient. Inter-observer and intra-observer variability were calculated. RESULTS: = 0.329). The intraclass correlation coefficient indicated that the inter-observer agreement was high (0.998). The standard deviation between repeated measurements was 1.9-5.3%. CONCLUSION: IDEAL sequences allow for the measurement EOM-SV both on non-contrast and contrast-enhanced scans. EOM-SV predicts proptosis more accurately than does EOM-CSA. The measurement of EOM-SV is practical and reproducible. EOM-SV changes of 3.5-8.3% can be assumed to reflect true volume changes.

Cite this record

Ludovico Maria Garau, Daniele Guerrieri, Flaminia De Cristofaro, Alice Bruscolini, Giuseppe Panzironi (2018). Extraocular muscle sampled volume in Graves’ orbitopathy using 3-T fast spin-echo MRI with iterative decomposition of water and fat sequences. Acta Radiologica Open, 7(6), 2058460118780892–2058460118780892. https://doi.org/10.1177/2058460118780892

Copy in another style

Garau, L. M., Guerrieri, D., Cristofaro, F. D., Bruscolini, A., & Panzironi, G. (2018). Extraocular muscle sampled volume in Graves’ orbitopathy using 3-T fast spin-echo MRI with iterative decomposition of water and fat sequences. Acta Radiologica Open, 7(6), 2058460118780892–2058460118780892. https://doi.org/10.1177/2058460118780892
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.