We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Chemical Engineering/Experimental Investigation of Focused Ultrasound Transmission through Rat Skulls
PeriodicalsChemical Engineering

Experimental Investigation of Focused Ultrasound Transmission through Rat Skulls

Checking your access to this record.

Abstract & Overview

Transcranial focused ultrasound (tFUS) is an emerging, noninvasive therapeutic approach for neurological conditions. However, its development is hindered by the skull, which serves as an important acoustic barrier. Although small animal models have been used extensively to study tFUS, the impact of the skull in these models remains poorly understood. To address this knowledge gap, this study experimentally examined the attenuation and defocusing effects of 2 ex vivo rat skulls on acoustic pressure fields at therapeutically relevant frequencies. Using 3 focused ultrasound transducers operating between 1 and 2.25 MHz, we evaluated the impact of rat skull characteristics, location of the focus, and frequency on ultrasound transmission loss, full width at half maximum (FWHM), and focal location. The results demonstrated that skull thickness and morphology substantially influence attenuation and defocusing. Higher frequencies, while offering sharper focus, also led to increased attenuation and defocusing. Furthermore, the position of the focus relative to the skull had a minimal effect on the outcomes. Overall, the presence of the rat skull resulted in a 50% to 88% reduction in focal intensity, a focal broadening of 1% to 53%, and a focal shift of −1.6 to 2.1 mm. These findings provide critical insights that can enhance the precision and efficacy of tFUS in preclinical applications using rats as a small animal model.

Cite this record

Saira Hussain, Hyeonu Heo, Yushun Zeng, Qifa Zhou, Yun Jing (2025). Experimental Investigation of Focused Ultrasound Transmission through Rat Skulls. Advanced Devices & Instrumentation, 6, 0122. https://doi.org/10.34133/adi.0122

Copy in another style

Hussain, S., Heo, H., Zeng, Y., Zhou, Q., & Jing, Y. (2025). Experimental Investigation of Focused Ultrasound Transmission through Rat Skulls. Advanced Devices & Instrumentation, 6, 0122. https://doi.org/10.34133/adi.0122
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.