We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Biomedical Engineering/Development, set-up and first results for a one-channel near-infrared spectroscopy system / Entwicklung, Aufbau und vorläufige Ergebnisse eines Einkanal- Nahinfrarot-Spektroskopie-Systems
PeriodicalsBiomedical Engineering

Development, set-up and first results for a one-channel near-infrared spectroscopy system / Entwicklung, Aufbau und vorläufige Ergebnisse eines Einkanal- Nahinfrarot-Spektroskopie-Systems

Checking your access to this record.

Abstract & Overview

Abstract Near-infrared spectroscopy (NIRS) is a non-invasive optical technique that can be used to assess functional activity in the human brain. This work describes the set-up of a one-channel NIRS system designed for use as an optical brain-computer interface (BCI) and reports on first measurements of deoxyhemoglobin (Hb) and oxyhemoglobin (HbO(2)) changes during mental arithmetic tasks. We found relatively stable and reproducible hemodynamic responses in a group of 13 healthy subjects. Unexpected observations of a decrease in HbO(2) and increase in Hb concentrations measured over the prefrontal cortex were in contrast to the typical hemodynamic responses (increase in HbO(2), decrease in Hb) during cortical activation previously reported.

Cite this record

Günther Bauernfeind, Robert Leeb, Selina Christin Wriessnegger, Gert Pfurtscheller (2008). Development, set-up and first results for a one-channel near-infrared spectroscopy system / Entwicklung, Aufbau und vorläufige Ergebnisse eines Einkanal- Nahinfrarot-Spektroskopie-Systems. Biomedizinische Technik/Biomedical Engineering, 53(1), 36–43. https://doi.org/10.1515/bmt.2008.005

Copy in another style

Bauernfeind, G., Leeb, R., Wriessnegger, S. C., & Pfurtscheller, G. (2008). Development, set-up and first results for a one-channel near-infrared spectroscopy system / Entwicklung, Aufbau und vorläufige Ergebnisse eines Einkanal- Nahinfrarot-Spektroskopie-Systems. Biomedizinische Technik/Biomedical Engineering, 53(1), 36–43. https://doi.org/10.1515/bmt.2008.005
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.