Radial-to-femoral pressure gradient quantification in cardiac surgery

Checking your access to this record.

Abstract & Overview

Background A radial-to-femoral pressure gradient (RFPG) can occur in roughly one-third of cardiac surgical patients. Such a gradient has been associated with smaller stature and potentially smaller radial artery diameter. We hypothesized that preoperative radial artery diameter could be a predictor of RFPG. We also investigated the clinical impact of using a femoral versus a radial arterial catheter in terms of vasoactive support. Methods Using ultrasound, we measured the bilateral radial artery diameters of 160 cardiac surgical patients. All arterial pressure values were continuously recorded. Significant RFPG was defined as ≥25 mm Hg in systolic and/or ≥10 mm Hg in mean arterial pressure. One hundred and forty-nine additional patients were used to validate the impact of our observations. Results Using 78,013 pressure datapoints in 129 patients, 34.8% of patients had an RFPG with a mean duration of 54 ± 48 minutes. Patients with a radial artery diameter <1.8 mm were more likely to have an RFPG (n = 14 [48.3%] vs 12 [22.2%]; P = .042). Patients with only a radial catheter received more phenylephrine ( P = .016) despite undergoing shorter and less complex procedures. In the validation cohort, similar observations were made, and patients with a radial artery catheter received a longer duration of vasoactive support in the intensive care unit. Conclusions A significant RFPG occurs in one-third of cardiac surgical patients and in 48% of those with a radial artery diameter <1.8 mm. The use of a single radial arterial catheter instead of dual radial and femoral catheters was associated with greater vasopressor requirements in the operating room and in the intensive care unit. We do not recommend the use of a single radial artery catheter in cardiac surgery.

Cite this record

Vincent Bouchard-Dechêne, Loay Kontar, Pierre Couture, Philippe Pérusse, Sylvie Levesque, Yoan Lamarche, et al. (2021). Radial-to-femoral pressure gradient quantification in cardiac surgery. JTCVS Open, 8, 446–460. https://doi.org/10.1016/j.xjon.2021.07.031

Copy in another style

Bouchard-Dechêne, V., Kontar, L., Couture, P., Pérusse, P., Levesque, S., Lamarche, Y., Denault, A. Y., Rochon, A. G., Deschamps, A., & Desjardins, G. (2021). Radial-to-femoral pressure gradient quantification in cardiac surgery. JTCVS Open, 8, 446–460. https://doi.org/10.1016/j.xjon.2021.07.031
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.