We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Medical Sciences/The influence of the bolus-surface distance on the dose distribution in the build-up region
PeriodicalsMedical Sciences

The influence of the bolus-surface distance on the dose distribution in the build-up region

Checking your access to this record.

Abstract & Overview

AIM: The aim of the paper is to examine the relation between the increase of the photon dose in water in the region of electronic disequilibrium - so-called build-up region - and the distance of the bolus from the water surface for the applied parameters of X-ray beams. MATERIALS AND METHODS: PDD measurements were carried out using the plane-parallel ionization chamber Markus in the automatic water phantom IBA BluePhantom with OmniPro-Accept V7 (IBA Dosimetry GmbH, Schwarzenbruck, Germany). All measurements were performed for different field sizes and for 6 MV and 15 MV X-ray beams, respectively. A water-equivalent RW3 slab (Goettingen White Water) produced by PTW was used as a bolus. RESULTS: Placing a bolus in an irradiated field changes the shape of the PDD curve in the build-up region in comparison with the one obtained for an open field. All results has been inserted in tables and figures. CONCLUSION: The closer the bolus is to the water surface, the smaller the depth of the maximum dose in the phantom for all investigated fields and energies. The changes in the build-up region are important, even if the bolus does not touch the surface of the water phantom. The influence of the bolus can be ignored when the bolus-surface distance equals 25 cm for 6MV X-ray beams and 39 cm for 15 MV X-ray beams.

Cite this record

Martyna Sroka, Jakub Reguła, W Lobodziec (2010). The influence of the bolus-surface distance on the dose distribution in the build-up region. Reports of Practical Oncology & Radiotherapy, 15(6), 161–164. https://doi.org/10.1016/j.rpor.2010.09.003

Copy in another style

Sroka, M., Reguła, J., & Lobodziec, W. (2010). The influence of the bolus-surface distance on the dose distribution in the build-up region. Reports of Practical Oncology & Radiotherapy, 15(6), 161–164. https://doi.org/10.1016/j.rpor.2010.09.003
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.