We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Artificial Intelligence & Machine Learning/CAD System Utilizing UNet and Hough Transform for Automated Measurement of Fetal Head Circumference and Age in 2D Ultrasound Images
PeriodicalsArtificial Intelligence & Machine Learning

CAD System Utilizing UNet and Hough Transform for Automated Measurement of Fetal Head Circumference and Age in 2D Ultrasound Images

Checking your access to this record.

Abstract & Overview

Two-dimensional (2D) medical ultrasound is a widely used imaging modality for the anatomical and functional assessment of fetal development due to its low cost, availability, real-time capability, and the absence of radiation hazards. Head circumference (HC) is an essential biometric to measure fetal growth. However, the low signal-to-noise ratio in ultrasound imaging can make it difficult for clinicians to identify the fetal plane correctly. Additionally, manually measuring HC can be expensive, involving accurately placing three minor and major parameter points from the ultrasound machine. To address these issues, research has been conducted to develop an automated system for measuring HC. This study presents a computer-aided diagnosis (CAD) system for the automatic measurement of fetal HC and fetal age using hybrid feature extraction. Using Convolutional Neural Networks (CNNs), self-supervised learning (SSL), vision transformers (ViTs), UNet deep learning model for segmentation, and Hough transform to measure performance, this study achieved higher performance compared to previous studies with a Dice similarity coefficient (DSC) of 97.23 ± 2.78, an average distance factor (ADF) of 2.8 ± 2.93 mm, a Jaccard Index of 88.57 ± 3.79, and an accuracy of 97.2%. After that, we enhance UNet using an attention mechanism that achieved a Dice coefficient of 98.5 ± 2.5, an ADF of 2.4 ± 2.8 mm, and an accuracy of 98.1%. This system provides a more cost-effective and accurate measurement of HC, aiding clinicians in assessing fetal development. Received: 14 February 2025 | Revised: 16 May 2025 | Accepted: 29 July 2025 Conflicts of Interest The authors declare that they have no conflicts of interest to this work. Data Availability Statement The data that support the findings of this study are openly available in GitHub at https://github.com/pranjalrai-iitd/Fetal-head-segmentation-and-circumference-measurement-from-ultrasound-images. Author Contribution Statement Hamzah Jaber: Conceptualization, Investigation, Resources, Data curation, Writing – original draft, Writing – review & editing. Ahmed Abed Mohammed: Methodology, Validation, Formal analysis, Writing – review & editing. Bo Zhang: Software. Maidi Qiu: Software. Mustafa M. Abd Zaid: Validation, Project administration. Putra Sumari: Visualization, Supervision, Project administration.

Cite this record

Hamzah Jaber, Ahmed Abed Mohammed, Bo Zhang, Maidi Qiu, Mustafa Majeed Abd Zaid, Putra Sumari (2025). CAD System Utilizing UNet and Hough Transform for Automated Measurement of Fetal Head Circumference and Age in 2D Ultrasound Images. Artificial Intelligence and Applications, 4(1), 101–110. https://doi.org/10.47852/bonviewaia52025416

Copy in another style

Jaber, H., Mohammed, A. A., Zhang, B., Qiu, M., Zaid, M. M. A., & Sumari, P. (2025). CAD System Utilizing UNet and Hough Transform for Automated Measurement of Fetal Head Circumference and Age in 2D Ultrasound Images. Artificial Intelligence and Applications, 4(1), 101–110. https://doi.org/10.47852/bonviewaia52025416
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.