Home/e-Resources/Dentistry/Effects of Dental Implant-abutment Interfaces on the Reliability of Implant Systems
Conference ProceedingsDentistry

Effects of Dental Implant-abutment Interfaces on the Reliability of Implant Systems

Checking your access to this record.

Abstract & Overview

In this paper, by analyzing the effects of two different kinds of implant-abutment connection interfaces under the same working condition on the mechanical and fatigue performances of the implant system as well as on the surrounding bones, we intend to study such effects on the reliability of the implants and provide a theoretical basis for the design and clinical application of dental implant systems. For the purpose, we adopt a 3-D modeling method to establish the model, and use FEA (finite element analysis) to carry out static mechanic and fatigue analysis on the implant system and its surrounding bones; then we make the two implant systems, and carry out fatigue tests on a dynamic fatigue testing machine to verify the FEA results. After comparing the results from the two different systems, we find that the stress distribution and fatigue safety factor of the system which has deeper axial matching of the taper connection are better than those of the other system, that is to say, between the two major elements of a implant system, the axial length of the connecting taper and the size of the hexagon, the former has greater effects than the latter. When the axial matching is deeper, the stress distribution of the implant system will be better, the fatigue safety factor will be higher, and the implant system will be more reliable.

Cite this record

Xiao Zhang, Lei Liu, Yaling Wang, Xianshuai Chen (2016). Effects of Dental Implant-abutment Interfaces on the Reliability of Implant Systems. MATEC Web of Conferences. https://doi.org/10.1051/matecconf/20167708006

Copy in another style

Zhang, X., Liu, L., Wang, Y., & Chen, X. (2016). Effects of Dental Implant-abutment Interfaces on the Reliability of Implant Systems. MATEC Web of Conferences. https://doi.org/10.1051/matecconf/20167708006
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.