Abstract & Overview
Over the years the functionality and performance of instrumentation used with head type has steadily improved. The technology employed in pressure instrumentation has resulted in a migration from mechanical/pneumatic transmitters to analog electronic transmitters to microprocessor based smart electronic transmitters. Similar improvements have occurred in temperature instrumentation. The logical next step in this progression is the consolidation of multiple process measurements in a single transmitter package. With all of the process measurements available, the benefits to the user can be further enhanced by performing flow calculation within the transmitter. The benefits of using the process variables to continuously calculate the terms in the equation for flow through a head type meters are presented. A comparison is made between this method and the commonly used method in which many terms are considered to be constant. Significant improvements can be realized by the real-time calculation of these terms, particularly the discharge coefficient and fluid density. Calculated performance results are presented for both liquid and gas flow application. The results show that a multiple process variable transmitter with on-board flow calculations can extend flow range beyond the typically accepted 3:1 range.