Generating synthetic images from cone beam computed tomography using self-attention residual UNet for head and neck radiotherapy

Checking your access to this record.

Abstract & Overview

Background and purpose: Accurate CT numbers in Cone Beam CT (CBCT) are crucial for precise dose calculations in adaptive radiotherapy (ART). This study aimed to generate synthetic CT (sCT) from CBCT using deep learning (DL) models in head and neck (HN) radiotherapy. Materials and methods: A novel DL model, the 'self-attention-residual-UNet' (ResUNet), was developed for accurate sCT generation. ResUNet incorporates a self-attention mechanism in its long skip connections to enhance information transfer between the encoder and decoder. Data from 93 HN patients, each with planning CT (pCT) and first-day CBCT images were used. Model performance was evaluated using two DL approaches (non-adversarial and adversarial training) and two model types (2D axial only vs. 2.5D axial, sagittal, and coronal). ResUNet was compared with the traditional UNet through image quality assessment (Mean Absolute Error (MAE), Peak-Signal-to-Noise Ratio (PSNR), Structural Similarity Index (SSIM)) and dose calculation accuracy evaluation (DVH deviation and gamma evaluation (1 %/1mm)). Results: Image similarity evaluation results for the 2.5D-ResUNet and 2.5D-UNet models were: MAE: 46±7 HU vs. 51±9 HU, PSNR: 66.6±2.0 dB vs. 65.8±1.8 dB, and SSIM: 0.81±0.04 vs. 0.79±0.05. There were no significant differences in dose calculation accuracy between DL models. Both models demonstrated DVH deviation below 0.5 % and a gamma-pass-rate (1 %/1mm) exceeding 97 %. Conclusions: ResUNet enhanced CT number accuracy and image quality of sCT and outperformed UNet in sCT generation from CBCT. This method holds promise for generating precise sCT for HN ART.

Cite this record

SA Yoganathan, Souha Aouadi, Sharib Ahmed, Satheesh Prasad Paloor, Tarraf Torfeh, Noora Al‐Hammadi, et al. (2023). Generating synthetic images from cone beam computed tomography using self-attention residual UNet for head and neck radiotherapy. Physics and Imaging in Radiation Oncology, 28, 100512–100512. https://doi.org/10.1016/j.phro.2023.100512

Copy in another style

Yoganathan, S., Aouadi, S., Ahmed, S., Paloor, S. P., Torfeh, T., Al‐Hammadi, N., & Hammoud, R. W. (2023). Generating synthetic images from cone beam computed tomography using self-attention residual UNet for head and neck radiotherapy. Physics and Imaging in Radiation Oncology, 28, 100512–100512. https://doi.org/10.1016/j.phro.2023.100512
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.