We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Dentistry/Extra-short implants in posterior maxillary vertical atrophy with low bone density: a retrospective analysis of cases with transcrestal sinus elevation and insertion torque ≤15 Ncm
PeriodicalsDentistry

Extra-short implants in posterior maxillary vertical atrophy with low bone density: a retrospective analysis of cases with transcrestal sinus elevation and insertion torque ≤15 Ncm

Checking your access to this record.

Abstract & Overview

Objectives: The aim of the present study is to analyze the survival and clinical performance of implants inserted in complex scenarios (≤6,5 mm residual bone height), with reduced insertion torque, using the transcrestal sinus elevation technique. Materials and Methods: A retrospective review was conducted of patients treated between 2017 and 2020 involving short and extra-short implants (BTI Biotechnology Institute, UnicCa® surface) placed in posterior maxillae with residual bone height ≤6,5 mm and final insertion torque ≤15 N cm. All implants were placed using the biological drilling technique at low speed, with transcrestal sinus elevation and grafting with autologous bone collected during drilling mixed with PRGF-Endoret. A two-stage protocol was followed, with second-stage surgery at 5 months and progressive loading. Radiographic evaluation of marginal bone loss was performed with standardized panoramic radiographs. Results: Seventeen patients (20 implants) with a mean age of 60.8 years were followed-up for a mean of 5.9 years. No implant failures occurred, yielding 100% survival. Mean marginal bone loss was 0.45 mm mesially and 0.43 mm distally. Correlation between insertion torque and bone loss showed weak, non-significant trends. Conclusions: Within the limitations of this study, extra-short implants placed with insertion torque ≤15 N cm in posterior maxillae with ≤6,5 mm residual bone height achieved excellent survival and minimal bone loss at medium-term follow-up. Keywords: Transcrestal sinus elevation, Extra-short implants, Low insertion torque, Posterior maxilla, Marginal bone loss, Bone antropy

Cite this record

Eduardo Anitua (2026). Extra-short implants in posterior maxillary vertical atrophy with low bone density: a retrospective analysis of cases with transcrestal sinus elevation and insertion torque ≤15 Ncm. Jordan journal of dentistry., 3(1). https://doi.org/10.14525/jjd.v3i1.02

Copy in another style

Anitua, E. (2026). Extra-short implants in posterior maxillary vertical atrophy with low bone density: a retrospective analysis of cases with transcrestal sinus elevation and insertion torque ≤15 Ncm. Jordan journal of dentistry., 3(1). https://doi.org/10.14525/jjd.v3i1.02
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.